background image

8 - Cleaning and used devices

Cleaning

To clean the thermostat use only a dry or lightly wet 

cloth. Avoid chemical solvent - it can probably dam-

age the device.

Used devices

Do  not  throw  old  devices  and  packaging  into  the 

household waste. They can be recycled. You receive 

further information at you local administration.

Data transmission

For the data transmission between the radio control 

and the thermostat control a particularly reliable ra-

dio transmission system is used (868 MHz). Owning 

the statutory regulations requiring the data transmis-

sion to be limited to max. 36 seconds per hour (1% 

duty-cycle)  the  likelihood  and  risk  of  interference 

with other radio services is minimized. 

The  data  transmission  to  the  individual  thermostat 

control is carried out in regular time pattern. Thus it 

can take up to 15 minutes for the data signal to get 

transmitted to the individual thermostat control.

Guarantee

The guarantee period is 24 months and it starts on 

the date on which the product was purchased by the 

end user. Please keep the purchase receipt for the 

duration of the guarantee period; it must be submit-

ted  for  a  guarantee  claim.  This  product  has  been 

manufactured using state-of-the-art production proc-

esses and in addition it has been subjected to rigor-

ous quality controls. Nevertheless if defects should 

occur  during  the  guarantee  period,  please  contact 

us at the address listed below. After the guarantee 

period all upcoming repairs are with costs. Your legal 

rights are not restrained by this guarantee.

Please  note  that  shipments  of  goods,  return  ship-

ments, and other shipments can only be accepted if 

postage/shipping charges are prepaid in full.

EUROtronic Technology GmbH

Südweg 1

D-36396 Steinau - Ulmbach

Phone:  +49 (0) 6667/ 919050

Email: 

[email protected]

Internet:  www.eurotronic.org

Packg.-No. 900 000 091 | version 07.2008

6 - Mounting

Sparmatic  premium  can  be  easily  mounted  on  all 

common  valve  bodies.  It  can  be  installed  without 

grime and water spots, because the heating circuit 

water is not interrupted. Loosen the fastening of the 

old thermostat head, pull the thermostat head off of 

the valve.

Select an adapter if necessary:

Adapters are required for some valve types. Prior to 

mounting, select the appropriate adapter as shown 

in the adapter table. If you require an adapter: Push 

the adapter onto the valve and turn it until it notice-

ably clicks into place. If the adapter is fi tted with a 

screw, tighten the adapter with the screw.

The instruction Inst is shown in the display. Sparmat-

ic premium can be quickly and easily mounted with 

a single hand movement. Hand-tighten the union nut 

Adapter table

Additional adapter types are listed at www.eurotronic.org

no adapter 
required

+ accompanying 

pin, only for RAV!

Heimeier, Junkers

Gyr, MNG, 

Honeywell, Braukmann

thread dimension of M 30x1,5

Danfoss RAV 

enclosed pin must be 

plugged on the valve tapped

Danfoss RA

Danfoss RAVL

Sparmatic  premium  works  like  a  standard  control 

without  any  radio  function  if  you  enter  00:00  as 

combination  for  house  code  and  room  zone  and 

confi rm with the 

    button. Then you are request-

ed for date and time. All values are set according to 

the enclosed manual for the Sparmatic basic. This 

device runs as a stand-alone-solution. All operation 

elements are active. Press the    button 

for 

more than 5 seconds to involve the device into your 

radio  system.  00:00  appears  in  the  display  to  re-

enter house code and room zone.

5.2 Adjusting temperature to local conditions / 

temperature-setup

 

Often the perceived temperature signifi cantly devi-

ates from the set thermostat temperature, for exam-

ple  due  to  spatial  distance  to  the  thermostat.  For 

this reason you should execute a temperature set 

up that is specifi cally adapted to your room situa-

tion. To do so press the 

   button for 5 seconds. 

The house code appears in the display. Press the 

  

button  again  for  5  seconds.  0.0°  appears. 

Now  set  the  desired  temperature  increase  at  the 

Sparmatic premium control. Confi rm with the  

button. The temperature shown in the LCD display 

does not change!

PROG

AUTO 

MANU

PROG

until the device is fi rmly fi xed on the valve body. 

7 - Adapting

Press any button and Sparmatic premium will start 

to  adapt.  The  device  will  adapt  itself  to  the  stroke 

of your valve body. To do this the valve will now be 

opened  and  closed  several  times  to  learn  the  end 

points. In some cases this process can take a few 

minutes. During this adaptation process ADAP will be 

shown in the display. 

After successful adaptation Sparmatic premium re-

turns to normal mode. Now it is ready to receive its 

programme from the control.

PROG

PROG

Help

Problem

Batt

Heating 

element 

does not 

cool down.

Heating 

element 

does not 

warm up.

E1

E2

E 3

FUFE

Cause

Batteries do not 

have enough power.

Valve does not 

close completely.

It may be that the 

closing point of 

your valve seat has 

shifted.

Valve does not 

open, is it calcifi ed 

after the summer 

pause / heating 

pause?

No adaptation 

possible.

Valve stroke is too 

short.

Motor movement is 

not possible.

No radio transmis-

sion between the 

thermostat control 

and the radio con-

trol for more than 

60 minutes.

Solution

Replace batteries.

Adapt again (see “Adapt-

ing”)

Move the valve stem 

several times by hand, it 

may be that adaptation is 

impossible because your 

valve is calcifi ed or the 

seat no longer performs 

its function.

Remove the Sparmatic 

premium, move the valve 

stem back and forth per 

hand or with a tool.

Is the installation OK?

Open and close the valve 

several times manually or 

replace the batteries.

Does the valve stem 

move freely??

Check the conditions on 

site. The position of the 

radio control may need to 

be changed.

Is the boiler water temperature OK??

Konformitätserklärung
Declaration of Confi rmity

Wir  

EUROtronic Technology GmbH, 

We  

Südweg 1, 36396 Steinau

erklären, dass das Produkt

declare that the product

elektronischer Heizkörperthermostat Sparmatic

electronic radiatorcontroller Sparmatic 

auf das sich diese Erklärung bezieht, mit folgenden Nor-

men übereinstimmt

to which this declaration relates is in confi rmity with the follo-
wing standard
International
International  EN 55022: 2006
 

EN 55024: 1998 + A1: 2001 + A2: 2003

 

EN 55014-1: 2006

 

EN 61000-4-2/ 2001

 

EN 61000-4-3/ 2002+A1

 

EN 60950-1: 2006

 

EN 60730-1-1: 2000+ A1: 2004

 

EN 61000-4-2/ 2001

 

EN 61000-4-3/ 2001+A1

 

R + TTE Richtlinie 99/5 EG

They bear the CE mark.

Steinau, 30.10.07

This declaration certifi es agreement with the directives cited, however 
it does not contain any assurance of characteristics.

Отзывы: