6. MAIN FUNCTIONS
6.1 TEMPERATURE SETTING
EIN
All 6 LEDs on > 28° = heating ON (valve fully open, no regulation)
LED 1 to 5 on, 6 flashes: 28°
LED 1 to 5 an: 26,5 °
LED 1 to 4 an, 5 flashes: 25°
LED 1 to 4 an: 23,5°
LED 1 to 3 an, 4 flashes: 22°
LED 1 to 3 an: 20,5°
LED 1 to 2 an, 3 flashes: 19°
LED 1 to 2 an: 17,5°
LED 1 to, 2 flashes: 16°
LED 1 to: 14,5
LED 1 flashes: 13°
no LED on: < 8° = heating OFF (anti-freeze function active)
The temperature can be set as desired using the
PLUS
and
MINUS
buttons. The temperature is always increased or
decreased in 1.5° steps.
To start the self-learning function (running time 24 hours), select the menu item Self-learning function in the
MENU
.
To do this, use
PLUS
and
MINUS
to navigate through the menu until the Self-learning function LED lights up. Now
confirm with OK/SET. The thermostat then goes into normal operation and displays the temperature via the LEDs. All
temperature changes that you make on the thermostat in the next 24 hours are now stored. After the 24 hours have
elapsed, heating is now carried out every day according to the same stored scheme.
6.2 SELF-LEARNING-FUNCTION