6.5 DISASSEMBLY
To remove GENIUS BLE 100, press the
MENU
button on your controller. USE
PLUS/MINUS
to navigate to the menu item for Assembly/Disassembly and confirm with
OK/SET.
A running light is indicated by the LEDs. Wait briefly until the setting LED flashes.
Now turn the union nut counterclockwise and remove the GENIUS BLE 100
from the valve (Fig. 7).
Fi
g.
7
After installation, GENIUS BLE 100 can start adapting. The LED for Assembly/Disassembly is already flashing,
confirm the adaptation by pressing and holding the OK/SET button (3 seconds). The adaptation starts after
confirmation. The device now adapts to the stroke of your valve body. To do this, the valve is now opened and closed
several times to learn the respective end points. A running light is indicated by the LEDs. After successful adaptation,
the GENIUS BLE 100 switches to normal operation and the LEDs indicate the setpoint temperature.
After approx. 5 seconds the thermostat switches to standby mode.
• If a new adaptation is necessary, e.g. if your radiator does not become cold in the OFF position, please select
Assembly/Disassembly in the menu. Confirm with
OK/SET
(3 seconds) and start the adaptation again
• When the Assembly/Disassembly LED flashes again, place the GENIUS BLE 100 on the radiator valve and then
briefly remove the batteries to reset.