17
16
Activate manually Window open detection
The „Window open detection“ is always active. Should
there still be performed a manual „Window open detec-
tion“, proceed as follows: Hold the
button on the
unit for about 2 seconds to activate the „Window open
detection“. The function now remains active as long
as you have selected your setting in the FRITZ!Box menu.
If this symbol is illuminated on the display, the „Window
open detection“ is activated. If you want the function to
end before the end of this time, press the
MENU
button on
the device.
Manual temperature setting
If, during operation, the target temperature is changed
manually on the device by means of the setting wheel,
this will remain until the next switching point, your set
time profile is not changed.
Setting Menu Comet DECT
Press
MENU
to enter the setting menu.
The various points can be selected with the setting
wheel. With
OK
select a menu item, with the setting
wheel the values can be changed.
OK
OK confirms an
entry, press the button
MENU
again to exit the menu.
FUNK SUCH
Search FRITZ!Box
ENTF
Delete device
RES
Reset the device to factory settings
ADAP
Start of a new adaptation of the valve adjustment
INST
Installation
function
(Device goes with PREP in the INST-position)
VERS
Firmware Version of the Comet DECT Controller
IPEI
The last 7 digits of the identification number
Frost protection function
The frost protection function is activated automatically.
If the temperature drops below 6 °C, Comet DECT opens
the valve until the temperature again rises above 8 °C.
Thus, freezing of the heater is prevented.
Calcification protection
The calcification protection is automatically active. In
order to prevent calcification of radiator valves, Comet
DECT performs 1x weekly (on Friday morning) an anti-
calcification process.
Heft-85x120mm-en.indd 16-17
Heft-85x120mm-en.indd 16-17
25.01.2016 15:52:21
25.01.2016 15:52:21