Chapter 5 Terminal Descriptions
582/583/5831
5 - 3
POWER TERMINALS
582
582
582
582
Input Terminals
:
L1 (L)
L2 (N)
L3
220/240V AC ± 10%
Single phase L and N
3-phase L1, L2, L3
Brake Connections
:
DC +
DC -
DC Link Positive
DC Link Negative
Motor Connections
:
M1 (U)
M2 (V)
M3 (W)
3-Phase
0 to 220/240V AC
0 to 100/120HZ
NOTE: The 582 has no chassis ground except when a gland plate is fitted. Power terminal blocks
are suitable for 2.5mm
2
wire (12 AWG) recommended tightening torque 0.5Nm (4.5 lb-in).
583
583
583
583
1
11
1
Input Terminals
:
L1 (L)
L2 (N)
L3
220/240V AC ± 10%
Single phase L and N
3-phase L1, L2, L3
Brake Connections
:
DC +
DC -
DC Link Positive
DC Link Negative
Health Relay
Health Relay
HEALTH
2
Contact rating 3A 250V AC/30V DC
Motor Connections
:
M1 (U)
M2 (V)
M3 (W)
3-phase
0 to 220/240V AC
0 to 100/120Hz
NOTE: The 583 can be grounded at the heatsink. Power Terminal Blocks are suitable for 4mm
2
wire
(10 AWG) recommended tightening torque 0.5Nm (4.5 lb-in).
5831
5831
5831
5831
1
11
1
Input Terminals
:
L1 (L)
L2 (N)
L3
220/240V AC ± 10%
Single phase L and N
3-phase L1, L2, L3
Motor Connections
:
M1 (U)
M2 (V)
M3 (W)
3-phase
0 to 220/240V AC
0 to 100/120Hz
Health Relay
Health Relay
HEALTH
2
Contact rating 3A 250V AC/30V DC
Brake Connections
(Faston Connectors)
:
DC +
DC -
DC Link Positive
DC Link Negative
NOTE: The 5831 can be grounded at the base plate. Power terminal blocks are suitable for 4mm
2
wire (10 AWG) recommended tightening torque 0.5Nm (4.5 lb-in).
NOTES:
1.
The ground terminal is indicated by the IEC grounding symbol thus:-
2.
Contacts closed when drive is healthy.
Содержание 582
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 38: ...Figure B Mounting Details for Filter Part Number CO389108 ...
Страница 39: ...Figure C Mounting Details for Filter Part Number CO389110 ...