Operating Instructions
Ed. 06/2006
23
WHAT TO DO IF THE RED LAMP LIGHTS UP
(ALL MODELS)
This appliance has an electronic flame supervision device. If the flame disappears the gas flow will be
automatically shut off and the red lamp will alight instead of the green one. The appliance will perform
a new lighting attempt if you do
ONE
of the following actions:
A. Turn off all electric supply to the appliance for some seconds then turn it on again;
OR
B. Turn the thermostat knob to zero setting, then turn it back to comfort setting after some seconds;
OR
C. Press the reset button once (5001/8001 models), or press the SUMMER/WINTER button to
SUMMER (button down) for some seconds, then push it back (button up) to WINTER position
(5002/8002 models).
HOW TO SHUT OFF THE APPLIANCE
1. Turn the thermostat knob to the ZERO position.
2. Turn the I–O switch on the programmable clock to ZERO position.
3. Turn off all electric supply to the appliance.
4. Turn the gas tap installed on the gas supply line upstream to the unit to
CLOSED
position.
USING YOUR 5001/8001 HEATER
GREEN LAMP
: it is alight when the flame is ON
RED LAMP
: in case the flame disappears the gas flow will be shut
off and the red lamp will alight instead of the green one. The unit is
locked–out. To reset the unit proceed as indicated in the tables
above (“WHAT TO DO IF THE RED LAMP LIGHTS UP”).
RESET BUTTON:
Press this to reset the unit if the red lamp will alight
instead of the green one (see above “RED LAMP”).
!
THERMOSTAT
: turn clockwise to increase the temperature, turn
counterclockwise to decrease it