HA250385
Issue 7 Nov 06
Page 128
MULTIPOINT CIRCULAR-CHART RECORDER: USER GUIDE
A1 TECHNICAL SPECIFICATION (Recorder)
Board types (I/O)
Universal input board, 6-Changeover relay output board, 4-Channel analog output (retransmision) board
Options (See options manual)
Host Communications
Memory Card
Transmitter Power Supply
Controllers (see also separate controller manual)
Also Case Heater (not described)
Environmental Performance
Temperature limits
0 to 50˚C operating (-20 to 50˚C with case heater)
With control, 0 to
≈
40˚C (depends on exact hardware configuration)
Humidity limits
10 to 90% non-condensing
Protection
door and bezel - IP54 (optional IP65)
Shock
BS EN61010, corner drop test & BS EN60873 edge drop test
Vibration
BS EN60873 (10 to 60 Hz @ .07 mm displacement; 60 to 150 Hz @ 1g)
Altitude (max)
< 2000 metres
Physical
Bezel size
360 High by 380mm wide (Bezel centreline offset 5 mm right with respect to cutout centreline - see fig 1.2.1)
Panel cutout dimensions
340.5 High by 345.5 wide (both – 0 + 2 mm)
Depth behind bezel rear face
150 mm
Weight
average 7 Kg (15 lbs)
Panel mounting
Ve 5/– 30 degrees (where + means top or recorder towards operator - see figure 1.2.1)
Printing system
Pen type
Four-nib cartridge
Print resolution
0.2 mm
Default trace colours
(can be changed during configuration)
Printhead life
1.0 x 10
6
dots per color - black has extra 50%
Update rate
2 Hz (1 Hz when supplied with derived channels, timers, archiving or retransmission)
Trace rate (maximum)
1 pass every 5 seconds
Characters per line
39
Electromagnetic compatibility (EMC)
Emissions:
BS EN50081-2
Immunity:
BS EN50082-2
Electrical safety
BS EN61010. Installation category
II
; Pollution degree
2
Paper transport
Type
Stepper motor
Chart speeds
1 to 960 hours per rev.
Chart type
12 hour; 24 hour; 7-day, not timed
Transport accuracy
0.25% single turn time accuracy
Power requirements
Line voltage
Standard:
90 to 264V; 45 to 65 Hz
Low voltage option:
20 to 53V ac (45 to 400 Hz) or dc (dc inrush-15A for 10ms @ 20V dc)
Power (Max)
100VA, ac; 60W, dc
Fuse type
None
Interrupt protection
Standard:
40ms at 75% max. instrument load
Enhanced:
120msec at 75% max. instrument load
Channel
1
2
3
Colour
Channel
Colour
blue
red
green
4
5
6
black
blue/red
green/black
Содержание 394
Страница 1: ...Model 394 Multi point circular chart recorder User Guide EUROT HERM ...
Страница 4: ......
Страница 122: ...MULTIPOINT CIRCULAR CHART RECORDER USER GUIDE HA250385 Issue 7 Nov 06 Page 118 This page is deliberately left blank ...
Страница 138: ...HA250385 Issue 7 Nov 06 Page 134 MULTIPOINT CIRCULAR CHART RECORDER USER GUIDE This page is deliberately left blank ...
Страница 140: ......
Страница 141: ......