CPU Temp. Limit of OFF [000]
Setting this value too high may cause the fan to stop when the CPU is at a high
temperature and therefore cause the system to be damaged.
The
CPU Temp. Limit of OFF
option can only be set if the
CPU FAN Mode Setting
option is set to
Automatic Mode
. Use the
CPU Temp. Limit of OFF
option to select the
CPU temperature at which the cooling fan should automatically turn off. To select a value,
select the
CPU Temp. Limit of OFF
option and enter a decimal number between 000
and 127. The temperature range is specified below.
Minimum Value: 0°C
Maximum Value: 127°C
CPU Temp. Limit of Start [020]
Setting this value too high may cause the fan to start only when the CPU is at a
high temperature and therefore cause the system to be damaged.
The
CPU Temp. Limit of Start
option can only be set if the
CPU FAN Mode Setting
option is set to
Automatic Mode
. Use the
CPU Temp. Limit of Start
option to select the
CPU temperature at which the cooling fan should automatically turn on. When the fan
starts, it rotates using the starting pulse width modulation (PWM) specified in the
Fan 3
Start PWM
option below. To select a value, select the
CPU Temp. Limit of Start
option
and enter a decimal number between 000 and 127. The temperature range is specified
below.
Minimum Value: 0°C
Maximum Value: 127°C
CPU Fan Start PWM [070]
The
Fan 3 Start PWM
option can only be set if the
CPU FAN Mode Setting
option is set
to
Automatic Mode
. Use the
Fan 3 Start PWM
option to select the PWM mode the fan
starts to rotate with after the temperature specified in the
Temperature 3 Limit of Start
is
exceeded. The Super I/O chipset supports 128 PWM modes. To select a value, select the
Fan 3 Start PWM
option and enter a decimal number between 000 and 127. The
temperature range is specified below.
PWM Minimum Mode: 0
PWM Maximum Mode: 127
Slope PWM [0.5 PWM]
The
Slope PWM 1
option can only be set if the
CPU FAN Mode Setting
option is set to
Automatic Mode
. Use the
Slope PWM 1
option to select the linear rate at which the
PWM mode increases with respect to an increase in temperature. A list of available
options is shown below:
0.125 PWM
0.25 PWM
0.5 PWM
1 PWM
Содержание ALUDRA
Страница 116: ...ALUDRA user manual Issue A 116 Appendix D Address Mapping I O Address Map ...
Страница 117: ...Appendix D Address Mapping Issue A 117 Table IO Address Map ...
Страница 118: ...ALUDRA user manual Issue A 118 IRQ Address Map Table IRQ Address Map ...
Страница 119: ...Appendix D Address Mapping Issue A 119 Memory Address Map Table Memory Address Map ...
Страница 123: ...www eurotech com ...