![Eurostove CHEW Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/eurostove/chew/chew_operation-manual_2440208002.webp)
2
Height
Width
Depth
Depth with Lip plate
Weight
CHEW
606
490
320
380
71 kg
SHEPPY
660
490
400
460
91 kg
Installation Manual and Operating instructions
CHEW 4.6 kW
SHEPPY 8 kW,
This manual refers to the stoves listed above, which are tested in accordance with EN 13240.
Congratulations on your purchase of a new stove from Eurotove Ltd. Please read this manual carefully to ensure that you
get maximum enjoyment from your new stove and to prevent any problems. Please note that “all local regulations, including
those referring to national and European Standards, need to be complied with when installing this appliance”.
For further information on installing and using fireplaces and wood burning stoves, please see the relevant building
regulations that apply to the country in which Chew and Sheppy models have been approved, as well as the relevant brochure
on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep.
These instructions cover the basic principals to ensure the satisfactory installation for Chew and Sheppy multi-fuel stove,
although detail may need slight modification to suit particular local site conditions.
STOVE PERFORMANCE & TESTING
Eurostove Chew & Sheppy stoves are approved and tested in accordance with EN 13240.
Output
wood fuel
Efficiency
CO@13%
o2
Recommended
for smoke control
Oct 2012
Output coal
fuel
Efficiency
CO@13% o2
Chew 5
4.6kw
80.0%
0.29
Yes / SE model
4.6kw
78%
0.15
Chew 8
8kw
80%
0.16
Yes / SE model
7kw
73%
0.06
Stove model
Weight & Nominal heat output for Wood and Smokeless fuels
Log length
Wood reload
Weight wood load
Coal reload
Weight coal (anth)
Chew 5
35cm
1hr
1.2kg
2hr
1.4kg
Chew 8
35cm
1hr
2.25 kg
2hr
2.25kg
Chimney Connection
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught to
clear the products of combustion and prevent smoke problems into the room.
Tested Gas flow rates flue
gas temperatures
Flue gas flow rate
Wood /coal
Test flue gas temperature
wood /coal
@ pascals of pressure
Chew 5
4.3/4.7 g/sec
231/221deg C
12 pa
Chew 8
5.8/7.1 g/sec
291/332deg C
12 pa
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the
chimney should be satisfactory. Alternately the calculation procedure given in BS 5854:1980 may be used as the basis for
deciding whether a particular chimney design will provide sufficient draught.