Eurostove CHEW Скачать руководство пользователя страница 2

2

Height

Width

Depth

Depth with Lip plate

Weight

CHEW

606

490

320

380

71 kg

SHEPPY

660

490

400

460

91 kg

Installation Manual and Operating instructions

CHEW 4.6 kW

SHEPPY 8 kW,

This manual refers to the stoves listed above, which are tested in accordance with EN 13240.

Congratulations on your purchase of a new stove from Eurotove Ltd. Please read this manual carefully to ensure that you

get maximum enjoyment from your new stove and to prevent any problems. Please note that “all local regulations, including
those referring to national and European Standards, need to be complied with when installing this appliance”.

For  further  information  on  installing  and  using  fireplaces  and  wood  burning  stoves,  please  see  the  relevant  building
regulations that apply to the country in which Chew and Sheppy models  have been approved, as well as the relevant brochure
on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep.

These instructions cover the basic principals to ensure the satisfactory installation for Chew and Sheppy multi-fuel stove,

although detail may need slight modification to suit particular local site conditions.

STOVE PERFORMANCE & TESTING

Eurostove  Chew &  Sheppy  stoves  are approved  and tested in accordance with EN 13240.

Output
wood fuel

Efficiency

CO@13%
o2

Recommended
for smoke control
Oct 2012

Output coal
fuel

Efficiency

CO@13% o2

Chew 5

4.6kw

80.0%

0.29

Yes / SE model

4.6kw

78%

0.15

Chew 8

8kw

80%

0.16

Yes / SE model

7kw

73%

0.06

Stove model 

Weight &  Nominal heat output for  Wood and  Smokeless fuels

Log length

Wood reload

Weight wood load

Coal reload

Weight coal (anth)

Chew 5

35cm

1hr

1.2kg

2hr

1.4kg

Chew 8

35cm

1hr

2.25 kg

2hr

2.25kg

Chimney Connection

In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught to
clear the products of combustion and prevent smoke problems into the room.

Tested Gas flow rates flue
gas temperatures

Flue gas flow rate
Wood /coal

Test flue gas temperature
wood /coal

@ pascals of pressure

Chew 5

4.3/4.7 g/sec

231/221deg C

12 pa

Chew 8

5.8/7.1 g/sec

291/332deg C

12 pa

NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the
chimney should be satisfactory. Alternately the calculation procedure given in BS 5854:1980 may be used as the basis for
deciding whether a particular chimney design will provide sufficient draught.

Содержание CHEW

Страница 1: ...1 OPERATION AND INSTALLATION MANUAL CHEW SHEPPY Multi fuel and SE models...

Страница 2: ...modification to suit particular local site conditions STOVE PERFORMANCE TESTING Eurostove Chew Sheppy stoves are approved and tested in accordance with EN 13240 Output wood fuel Efficiency CO 13 o2 R...

Страница 3: ...IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove because this can cause...

Страница 4: ...fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and...

Страница 5: ...sh off with damp cloth If the stove has not been used for some time the flue should be checked for blockages before use Do not modify the appliance only use spares authorised by the manufacturer B C E...

Страница 6: ...les regarding the minimum distance to non flammable walls Eurostove recommend leaving a gap of at least 10 cm behind and to sides of stove Eurostove Insulated chambers Eurostove Stoves are lined with...

Страница 7: ...venting the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened the smell will disappear This stove is NOT designed to be used with th...

Страница 8: ...for smoke control areas see page 4 alterations should not be attempted Eurostove smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel...

Страница 9: ...wood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood Do not burn liquid fuels drift wood finished sawn wood pallet wood chipboard plywood varnish...

Страница 10: ...otect your hand from possible heat The handle has push pull motion as shown above When shutting the door push the door closed and push handle firmly until the door latches PARTS Always use the operati...

Страница 11: ...ind it and this must be cleaned out Check the quality of all insulated panels and replace any which are damaged or cracked replace stove door rope cord in the door Check glass is correctly positioned...

Страница 12: ...moke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the height of the chimney relative to the surroundings 6 Soot in the chimney a The firewood may be too wet b i...

Отзывы: