Switching off the heating automatically in case of outdoor temperature increase. 

2.2. DHW circuit 

 filling the DHW tank

 

 

Controlling the weekly schedule 

 

DHW priority 

 

Temporary limitation of DHW priority 

 

Disinfection of DHW circuits - with the schedule of periodic disinfection.

 

2.3. DHW circulation circuit

 

 

Controlling the weekly schedule 

 

Time-base control (without temperature control)

 

2.4. Feeding 

 

 

Automatic identification of the preset temperature and control of the heating source  

 

Weekly schedule of the heating source operation 

 

Cooperation with the heat buffer  

 

Possible operation with two heating sources   

 

Possible  operation  without  feeding  temperature  sensor  (cooperation  with  heat 
distribution units). 

2.5. Utility functions

 

 

Control of a gas-fired boiler or other heating devices with a voltage-free output (NO/NC 
relay contacts) 

 

Alarm output (230 V 50 Hz output) 

 

Event log (the controller stores 15 last alarms or irregular situations) 

 

Supported languages: Polish, English, German 

 

Possibility to test each output 

 

Overheating protection 

 

Cooperation with systems with high feeding temperature (up to 110°C) –

 

on customer’s 

request 

 

Frost protection 

 

Anti-Stop algorithm 

 protection of pumps and valves against seizure.

 

 

Caution! The controller does not communicate with UNI2 and UNI3 controllers. 

3. USER INTERFACE 
3.1. Main screen

 

The following information is shown on the main screen: 

 

Zone temperatures: current and preset (calculated with a weather-based algorithm) 

 

Active devices (pump, mixer, boiler) 

 

Controller status (anti-stop, disinfection, heating season: WINTER/SUMMER and others) 

 

Time and date. 

An example screen with a description is shown below: 

Additional heating source on (feeding no.2, without the buffer)   

 

Содержание UNI4

Страница 1: ...manual carefully Manual version 01 02 2021 1 APPLICATION UNI4 is a universal controller designed to control a heating system equipped with Two independent CH zones with mixing valves e g for floor hea...

Страница 2: ...zone temperature sensor S5 CH2 zone temperature sensor R1 CH1 zone room thermostat R2 CH2 zone room thermostat P1 CH1 zone pump P2 CH2 zone pump P4 DHW circulation pump M1 230 V 3 point actuator of t...

Страница 3: ...of a gas fired boiler or other heating devices with a voltage free output NO NC relay contacts Alarm output 230 V 50 Hz output Event log the controller stores 15 last alarms or irregular situations S...

Страница 4: ...ation selecting between menu items up down next previous and a confirmation button located in the center of the knob which also clears the display of alarm warnings CAUTION When changing a setting the...

Страница 5: ...cted days of the week DHW circulation circuit schedule With the use of schedule we may preset the time of DHW circulation circuit operation on selected days of the week Heating season Switching to the...

Страница 6: ...ity to achieve thermal comfort regardless of external temperature The only requirement is to connect an outdoor temperature sensor After switching the weather compensation on temperatures of the CH zo...

Страница 7: ...ection at 0 00 The proper cleansing consists in heating the DHW tank to the temperature of 70 C and flushing the pipes with hot water The disinfection icon active in the display may last for 2 hours m...

Страница 8: ...proximate to alarm temperatures It is important to ensure a safe level of alarm temperature for each zone Pump starting temperature Above this temperature the pumps of CH 1 CH 2 zones and DHW circuit...

Страница 9: ...uirements Do not install the controller in rooms of increased humidity protect it against water and other liquids The controller is designed to be mounted on a 35 mm DIN rail in a protective cabinet D...

Страница 10: ...hermostat control may be switched on or off for each central heating zone It is only allowed to use thermostats with a voltage free normally open NO contact It is recommended to use Euroster devices T...

Страница 11: ...EUROSTER UNI4 USER MANUAL 11 Connection diagram for the cooling mode...

Страница 12: ...xceeds the required one CH circulation pump is switched on if heating is active and the mixer is not closed However if maintenance operation continuous operation was activated the pump operates withou...

Страница 13: ...hen thermostat output is disconnected after reaching the preset temperature in rooms 5 7 Buffer Pump Output Feeding no 2 voltage type This output is used to control the buffer pump the pump of additio...

Страница 14: ...nected inversely and whether it is not jammed 6 2 A selected zone is subject to overheating Check Whether the valve is not blocked Whether the mixer actuator is operating Whether the actuator cables a...

Страница 15: ...the Directive 2006 66 EC of the European Parliament and the Council Such marking informs that the electrical and electronic equipment and batteries may not be disposed of together with other househol...

Страница 16: ...on the day when the manufacturer received the claimed device 5 The device may be repaired exclusively by the manufacturer or by a party clearly authorized by the manufacturer 6 Warranty becomes void i...

Отзывы: