EUROSTER 1100Z – USER MANUAL
2
a. mounting of the controller:
•
the controller is fixed directly to the wall or to any other support with two screws
(plastic plugs c/w screws are part of delivery)
•
the cables extending from the controller are fixed to the wall with cable clips
b. mounting of the temperature sensor:
•
the sensor is NOT intended for immersion in liquids and installation on
breechings (flues between the boiler and chimney)
•
install the heating water temperature sensor on the bare outlet pipe of the boiler (as
close to the boiler as possible) or on the hot water cylinder
•
install the DHW temperature sensor on the hot water cylinder (cable marked with a
black sleeve)
c. connecting of the power supply cable to the heating water circulating pump:
•
connect the yellow or yellow/green wire (protective conductor) to terminal (
)
•
connect the blue wire to terminal (N)
•
connect the brown wire to terminal (L)
d. connecting of the power supply cable to the DHW circulating pump (marked with a
black sleeve):
•
connect the yellow or yellow/green wire (protective conductor) to terminal (
)
•
connect the blue wire to terminal (N)
•
connect the brown wire to terminal (L)
e. check-up of connections:
•
make sure the connections have been made as indicated and secure the cover of the
pump motor terminal box
f. connection of the controller:
•
upon securing the cables against accidental pullout,
connect the power supply cable
to a 230V/50Hz grounding socket.
IMPORTANT:
At the mounting location of the controller ambient temperature should not
exceed 40ºC.
3. OPERATION
After switching on the controller allow ca. 60 sec. for the controller to become fully
operational
a. start up:
•
set the left-hand toggle switch (~) to position I,
•
upon energising all the segments of the display light up for ca. 2 seconds,
•
the current temperature, as measured by the sensor is displayed and the controller
operates according to the factory settings (temperature limit of 50°C).
b. description of display functions
•
display continuously on – current temperature, as measured by the sensor,
•
blinking display – temperature setpoint,
•
red LED on – controller is switched to DHW mode
•
green LED on – controller is switched to heating mode
•
dot appears after the second figure – DHW priority is on
c. viewing of DHW temperature
•
for viewing the DHW temperature simultaneously press and release the two switches.
The current temperature, as measured by the DHW sensor will be displayed. After 5
sec. the heating water temperature will return to the display.