background image

202005-434-ENG 

User manual - Mixpro 100

P11

4. USE OF THE MACHINE (continued) 

4.2. STARTING UP

1. 

Once the machine is plugged in, the display (J) shows AU (emergency stop). Turn the red button (AU) 

to deactivate it.

2. 

The display (J) shows OFF, push the button ON/OFF (1) to switch on the machine.

3. 

The display (J) corresponds to the mixing speed from 0 to 100%, the display (K) shows the water 

dosage in litres.

4. 

Verify on the bag of the product to be mixed the water quantity and the necessary mixing time.

5. 

Using the /- (8) and (9), set the water quantity to the inferior value given by the product 

manufacturer.

6. 

Press the button DOSAGE (6). The water starts to run into the tank.

7. 

Using the /- (4) and (5), set the mixing speed to 80% and activate the mixing by pressing 

on the button MIXING (2).

8. 

Once the desired water quantity is in the tank (after the automatic stoppage of the water dosing), 
break the bag of powder and empty it.

9.  Mix the product for the time indicated by the product manufacturer.
10. 

If the product is too dry, use the +WATER button to add some water. The display (K) increments the 
value of the injected water quantity.

11. 

If you had to add some water, correct the initially set quantity with help of the /- (8) and (9).

12.  Press the EMPTYING button (3) and open the trapdoor (B).
13.  Once the product has been emptied, close the trapdoor (B).
14. 

Press the button DOSAGE (6) to once again pour water into the tank, then press the button MIXING (2).

15. 

Once the automatic water dosing has stopped, break the bag of powder and empty it.

16.  Mix the product for the amount of time indicated by the product manufacturer.
17.  Repeat from step 12 as frequently as necessary.

4.3. ERROR CODES

The different error codes show up on the display (J).

CODES

DEFINITION

TO DO

No display.

Plug the machine into the power supply, assure the power supply is 

230 V, verify the fuse in the electric box.

Emergency stop is 
on.

Unlock the emergency stop button (AU).

Machine is in the 
stop mode.

Switch the machine on by pressing on the button (1).

Default control 
engine.

Set the machine to OFF for one minute and then switch it back on.

Default security 
sensor.

Verify that the security grid is closed.

If the problem persists or if in doubt on the good running of the machine, do not try to repair 
it by yourself or to dismantle it.
Contact an authorized After-Sale Service or our hotline : +33 4 42 29 08 96.

Содержание MIXPRO 100

Страница 1: ...venue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 Mixpro 100 User manua...

Страница 2: ...t acquired EUROPE PROJECTION 228 avenue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SUMMARY 1 USER MANUAL p 3 1 1 Importance of the manual p 3 1 2 Receivers of the manua...

Страница 3: ...y the non compliance of the safety standards and rules This manual must be kept near the machine within reach of the user and held in good condition until the final destruction of the machine In case...

Страница 4: ...water jet or flammable liquid on the machine Never direct an air jet or product jet on a person or an animal Do not touch warm surfaces of the equipment Always wear adequate body protections glasses g...

Страница 5: ...ll as children and animals In case of installation of the machine on scaffolding or a plan above ground level attach the machine to avoid any fall while operating Do not install the equipment on an in...

Страница 6: ...entirely otherwise the equipment can be damaged The section must be proportional to the length of the cord 2 3 END OF LIFE OF THE PRODUCT At its end of life the machine must not be eliminated with the...

Страница 7: ...der products All bi component products Sand or lime to mix with water 3 2 TECHNICAL CHARACTERISTICS Machine compatible with CP Joint 10 CP 10 15 20 25 30 35 40 45 50 Mixing type sequential Motor 2 2 k...

Страница 8: ...005 434 ENG P8 3 YOUR MACHINE continued 3 3 IDENTIFICATION OF THE COMPONENTS A Safety grid B Emptying trapdoor C Folding feet D Water inlet quick connect E Geared motor F Command panel see details on...

Страница 9: ...in litres 1 Start Stop 8 Increase of the preset water volume 2 Start Stop of the mixing 9 Decrease of the preset water volume 3 Start Stop of the tank emptying L1 Power on light 4 Increase the motor...

Страница 10: ...the speed of rotation One push on the button EMPTYING 3 provokes the rotation of the mixer in emptying mode backwards rotation and the light L4 lights up WATER DOSAGE Set the wanted water quantity wit...

Страница 11: ...the value of the injected water quantity 11 If you had to add some water correct the initially set quantity with help of the arrows 8 and 9 12 Press the EMPTYING button 3 and open the trapdoor B 13 On...

Страница 12: ...e mixing blades think of turning them during the procedure Also clean the security grid A Once the operation is finished close the security grid Then clean the emptying trapdoor B 5 2 SERVICING Once a...

Страница 13: ...e R 233 73 article of the Labour Code THE DIRECTIVES Machines 2006 42 CE Low voltage 2014 35 UE CEM 2014 30 UE ROHS 2011 65 UE Noise emissions 2005 88 CE AND WITH THE STANDARDS NF EN ISO 12100 NF EN 6...

Страница 14: ...User manual Mixpro 100 202005 434 ENG P14...

Страница 15: ...ere totally or partially dismantled Defective equipment will be removed by us Any shipment of equipment by the customer will be at its own expense The guarantee will be subject to the presentation of...

Страница 16: ...avenue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 User manual Mixpro 1...

Отзывы: