3. WARNING (continued) 

3.2. ELECTRIC CONNECTION

The electric connection of the machine must be on a 16A - 230V plug with a differential circuit 

breaker .

Before any intervention on the machine, make sure that every energy supply is cut (air and 

electricity) .

GROUND CONNECTOR

All the machines must be connected to the ground when they work to protect the operator from electric 

shocks. Our machines are all equipped with standardized connection plugs.

Electric connection must be made by a qualified technician. It is fobidden to modify or dismantle the 

machine, especially the electric box .

Repairs must be made by an authorized center or our After-sale Service .

During any intervention on the machine, make sure that the ground is well reconnected.

EXTENSION CORDS

During the use of an extension cord, make sure that it is not crushed or damaged and that it contains a 

ground. Check that the section of the used extension cord is sufficient to support the machine when it 

is working. A too thin extension cord can cause voltage drops or overheating of the machine.

In case of use of a cable reel, it is imperative to unwind it entirely, otherwise, the equipment can be 

damaged . The section must be proportional to the length of the cord .

3.3. END OF LIFE OF THE PRODUCT

At its end-of-life, the machine must not be eliminated with the other household waste. The  

uncontrolled elimination of waste can harm the environment or human health. Individuals are 

invited to contact the distributor which sold them the product or to inquire with their city hall 

to know where and how to get rid of the product so it can be recycled while respecting the 

environment .

Under the regulation of Waste of Electrical and Electronic Equipments (WEEE), we undertake 

to process the used EEEs according to the following provisions: applicable only to products on 

the market since 08/13/05, under the brands EUROPE PROJECTION or VOLUMAIR, products 

of other brands sold by our company (upon presentation of the corresponding invoices), 

products that operate using electrical energy (for example, thermal washers or compressors 

do not fall into this category) .

Treatment modality

WEEE returns collected by our clients/distributors at their own expense to our collection points 

in Antony (92) or Rousset sur Arc (13) . Upon receipt, the products are sorted by our employees 

and directed to the most appropriate processing channels .

For any further information, please contact our hotline to conseil@euromair .com or

+33 4 42 29 08 96 .

Содержание MINIJET 120

Страница 1: ...RO 80 100 120 Ref 30555 30795 30685 EUROPE PROJECTION 228 avenue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 SIREN 394 961 510 NAF 2892 Z Editi...

Страница 2: ...User manual JETPRO 80 100 120 201902 338 ENG P2...

Страница 3: ...9 4 1 Description p 9 4 2 Technical characteristics p 9 4 3 Identification of the components p 10 5 USE OF THE MACHINE p 12 5 1 Prerequisites p 12 5 2 Starting up p 12 5 3 Error codes p 13 6 MAINTENAN...

Страница 4: ...ional equipments for paint and fillers we have put our know how for 20 years at the service of the users of our machines Our technical and commercial team is at your disposal for any further informati...

Страница 5: ...ed by the non compliance of the safety standards and rules This manual must be kept near the machine within reach of the user and held in good condition until the final destruction of the machine In c...

Страница 6: ...running abnormally or it is defective Do not direct a water jet or flammable liquid on the machine Never direct an air jet or product jet on a person or an animal Do not touch warm surfaces of the equ...

Страница 7: ...f the machine on scaffolding or a plan above ground level attach the machine to avoid any fall while operating Do not install the equipment on an inclined surface to avoid the risks of unexpected move...

Страница 8: ...t entirely otherwise the equipment can be damaged The section must be proportional to the length of the cord 3 3 END OF LIFE OF THE PRODUCT At its end of life the machine must not be eliminated with t...

Страница 9: ...avy loadings 4 2 TECHNICAL CHARACTERISTICS JETPRO 80 JETPRO 100 JETPRO 120 Maximum working pressure 80 bar 120 bar 120 bar Maximum product flow rate 6 L min 7 L min Electric motor 1 85 kW 2 2 kW 3 kW...

Страница 10: ...al JETPRO 80 100 120 201902 338 ENG P10 4 YOUR MACHINE continued 4 3 IDENTIFICATION OF THE COMPONENTS A Toolbox B Manometer C Pump D Drain valve E Spray gun F Nozzle G Control panel see next page B E...

Страница 11: ...s only while you press increases the motor speed decreases the motor speed PRIMING SPRAYING choice of PRIMING or SPRAYING mode Emergency stop Light Power on Light Manual process is selected Light Auto...

Страница 12: ...the display A1 to 50 with help of the buttons 4 5 push the button 2 to verify the correct start up After a prolonged standstill it is possible that the pump might be blocked If this is the case proce...

Страница 13: ...t the nozzle carrier onto the spray gun and use the desired nozzle for the used product 13 Set the working pressure on the display A1 to 60 with help of the buttons 4 or 5 14 Open the spray gun and ve...

Страница 14: ...ill the tank with water 8 Push the button MANU AUTO to put the machine in MANU mode the warning light L2 lights up 9 Set the display A1 to 50 with help of the buttons 4 5 10 Wait until the cleaning ba...

Страница 15: ...201902 338 ENG User manual JETPRO 80 100 120 P15 6 MAINTENANCE continued 6 2 DISMANTLING 1 3 4 2 5 6 7 8 8mm 9 10...

Страница 16: ...User manual JETPRO 80 100 120 201902 338 ENG P16 11 12 6 MAINTENANCE continued 6 2 DISMANTLING continued...

Страница 17: ...201902 338 ENG User manual JETPRO 80 100 120 P17 17 13 14 15 16 15 6 MAINTENANCE continued 6 3 REASSEMBLY...

Страница 18: ...User manual JETPRO 80 100 120 201902 338 ENG P18 25 23 22 24 21 18 19 20 6 MAINTENANCE continued 6 3 REASSEMBLY continued...

Страница 19: ...See procedure 5 1 page 12 The machine does not start at the opening of the lance Verify that the connectors are well connected The pressure is insufficient Verify that the setting is strong enough Ver...

Страница 20: ...120 COMPLIES WITH THE ARTICLE the R 233 73 article of the Labour Code THE DIRECTIVES Machines 2006 42 CE Low voltage 2014 35 UE CEM 2014 30 UE ROHS 2011 65 UE AND WITH THE STANDARDS NF EN ISO 12100 N...

Страница 21: ...OPE PROJECTION Model JETPRO spray gun Working pressure 19 MPa COMPLIES WITH THE ARTICLE the R 233 73 article of the Labour Code THE DIRECTIVE Machines 2006 42 CE AND WITH THE STANDARD NF EN 1953 ROUSS...

Страница 22: ...ch the serial number was erased or made illegible on which unauthorized people made attempts of repair which were totally or partially dismantled Our equipments are covered by a warranty parts and lab...

Страница 23: ...and if the use was in conformity with the instructions present in the user manual Based on this warranty the manufacturer will repair or replace free of charge any part that can deteriorate itself or...

Страница 24: ...manual JETPRO 80 100 120 201902 338 ENG P24 EUROPE PROJECTION 228 avenue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 SIREN 394 961 510 NAF 289...

Отзывы: