SANDBLASTER 0701AREN10MAS
11
Turn the control until the manometer shows that the appropriate working pressure
has been reached.
Press the control down to lock the regulator.
The working pressure must never exceed 6 kg/cm
2
(this is the maximum pressure on
the safety valve). It is considered that the optimal working pressure range is from 3.5 to
5.5 kg/cm
2
.
The working pressure depends on the type of work to be done.
7.4. ABRASIVE PRODUCT OUTLET FLOW REGULATION
The abrasive product outlet flow can be regulated by manually operating the product
outlet regulation control
[Exploded view 1
– Position 7]
, placed in the lower part of the tank.
The beginning of the adjustment process must be done with the regulator completely
closed (control fully tightened), carrying out its slow and gradual opening until reaching the
abrasive outlet flow rate suitable for the type of work to be done. The adjustment process must
be carried out with the gun trigger
[Exploded view 2
– Position 59]
pushed.
8. DISMANTLING OF COMPONENTS
The way to proceed to perform certain tasks of dismantling or replacement of
components of the equipment that are considered usual and can be carried out by the user
himself are described below.
8.1. DISMANTLING OF NOZZLES
To dismantle the nozzle of the gun
[Exploded view 2
– Position 52]
for cleaning or
replacement, proceed as follows:
Disconnect the equipment from the pressurized air power supply.
Unscrew the nozzle nut
[Exploded view 2
– Position 51]
from the adaptor
[Exploded view 2
–
Position 50]
attached to the product hose.
Remove the nozzle
[Exploded view 2
– Position 52]
from the nozzle nut
[Exploded view 2
–
Position 51]
.
To assemble the nozzle again, proceed in the opposite direction to the steps described
above.
8.2. DISMANTLING OF THE PRODUCT HOSE
To dismantle the product hose
[Exploded view 2
– Position 28],
for cleaning or replacement,
proceed as follows.
Disconnect the equipment from the pressurized air power supply.
Loose the clamp
[Exploded view 2
– Position 25]
that fixes the hose
[Exploded view 2
–
Position 28]
to the fitting
[Exploded view 2
– Position 24]
.
WARNING:
Never dismantle the regulation screw while the equipment is working. Once the
maximum output flow rate has been reached, the regulation screw must not continue
to be turned
[Exploded view 1
– Position 7]
in the opening direction, as it could be
accidentally dismantled.