5. DEFECTS AND REMEDIES 

Defect

To check

Remedy

Abnormal pressure oscillations

•  The pump sucks air.

•  Check the suction hoses.

• 

Water supply filter worn, dirty 

or clogged.

• 

Clean or change the filter.

The  pump  operates  without 

reaching the required pressure

• 

Unsuitable or worn nozzle.

•  Change the nozzle.

• 

Worn gaskets.

•  Change the gaskets.

Pressure drops

• 

Worn nozzle.

•  Change the nozzle.

• 

Worn valve.

•  Change the valve.

• 

Dirty water supply filter.

• 

Clean or change the filter.

• 

Adjustment  by-pass  worn  or 

clogged.

•  Clean or change the by-pass.

• 

Worn gaskets.

•  Change the gaskets.

Abnormal noise

•  Air suction.

•  Check the suction hoses.

• 

Worn or dirty bypass.

•  Clean or change the by-pass.

• 

Worn bearings.

•  Change the bearings.

Oil leaks

• 

Worn oil gaskets.

•  Change gasket kit.

Water in oil

• 

Worn oil or water gaskets.

•  Change gasket kit.

Water leakage from the lance

• 

Worn seals.

•  Change gasket kit.

In case of an unknown defect or a doubt on the good running of the machine, do not try to 
repair it by yourself or to dismantle it.
Contact an authorized After-Sale Service or our hotline : +33 4 42 29 08 96.

Before loosening the hose, make sure it is no longer under pressure.

Содержание EUROPROLAV 15-200 TH.2

Страница 1: ...Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 EUROPROLAV 15 200 15 250 18 280 TH...

Страница 2: ...further information you may need about the machine you just acquired EUROPE PROJECTION 228 avenue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SUMMARY 1 USER MANUAL p 3 1...

Страница 3: ...are caused by the non compliance of the safety standards and rules This manual must be kept near the machine within reach of the user and held in good condition until the final destruction of the mac...

Страница 4: ...nt in case of necessity Never use the equipment while it is running abnormally or it is defective Do not direct a water jet or flammable liquid on the machine Never direct an air jet or product jet on...

Страница 5: ...xpected moves or falls HOSES Always use hoses and connectors original parts with appropriate maximum pressure characteristics do not attempt to repair them Do not walk on the hoses do not bend them Do...

Страница 6: ...ergent suction 3 2 TECHNICAL CHARACTERISTICS 15 200 TH Kohler 15 200 TH Honda 15 250 TH Honda 18 280 TH Honda Variable pressure 0 to 200 bar 0 to 250 bar 0 to 280 bar Flow rate 15 L min 18 L min Nozzl...

Страница 7: ...15 200 15 250 18 280 TH 2 P7 3 YOUR MACHINE continued 3 3 IDENTIFICATION OF THE COMPONENTS A Water supply hose B Lance C Engine D High pressure hose E Pump F By pass G Manometer H High pressure outle...

Страница 8: ...ss the trigger on the lance water will come out of the nozzle at low pressure 4 After making sure the tank contains gasoline open the fuel supply 5 Engage the starter 6 Put the accelerator on full thr...

Страница 9: ...Clean or change the filter Adjustment by pass worn or clogged Clean or change the by pass Worn gaskets Change the gaskets Abnormal noise Air suction Check the suction hoses Worn or dirty bypass Clean...

Страница 10: ...H 2 15 250 TH 2 18 280 TH 2 COMPLIES WITH THE ARTICLE the R 233 73 article of the Labour Code THE DIRECTIVES Machines 2006 42 CE CEM 2014 30 UE ROHS 2011 65 UE Noise emissions 2005 88 CE AND WITH THE...

Страница 11: ...s cylinders piston rods prime spray valve assy seal kits membranes suction and delivery valves carding machine vanes filters oils The warranty also excludes the equipments on which the serial number w...

Страница 12: ...r Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 User manual EUROPROLAV 15 200 15...

Отзывы: