User manual - EUROPROLAV 15-200, 15-250, 18-280 TH.2
202006-445-ENG
P8
4. USE OF THE MACHINE
4.1. PREREQUISITES
•
The connection to the water supply must be made on an inlet with a sufficient flow rate, with a minimum
Ø19 hose to be connected to the pump’s quick coupling.
• The high pressure hose is connected to the connection at the pump by-pass outlet.
•
The engine must be stopped when filling the fuel tank.
•
Never operate the washer without a water supply, as this could cause serious damage to the pump.
•
The temperature of the water used must not 60°C.
4.2. STARTING UP
1. Check the oil level and then turn the engine button to the ON position.
2.
After connecting the washer to the water supply, open the water supply completely.
3.
Press the trigger on the lance, water will come out of the nozzle at low pressure.
4. After making sure the tank contains gasoline, open the fuel supply.
5. Engage the starter.
6. Put the accelerator on full throttle.
7.
Start the engine by pulling on the starter, with the trigger held in.
8.
Release the trigger and let the engine warm up for a few moments.
9. Turn the starter off.
10.
The cleaner is ready for use. To adjust the working pressure, turn the black knob on the by-pass and
check the pressure set on the manometer.
ENGINE SHUTDOWN
Turn the button to the OFF position and shut off the fuel supply.
Before each use of the washer, check the engine and pump oil levels using the dipsticks
intended for this purpose.
Do not use the washer in a closed room or in an area where the temperature is below 0°C.
After each engine shutdown, it is important to relieve the pressure remaining in the hose. To
do this, press the trigger on of the lance.