l
System guided walk test
with report - "Force call" feature for simple remote tech. support.
l
Bell & Auxiliary fuse monitoring
- Low/missing battery monitoring - Mains fail and restore
indication.
l
2 x on-board fused bell/siren outputs
- 4 x on-board open collector outputs for digital
communicator, etc.
General Features
The Verifier 24/64 offers 2 types of system operation - STANDARD (Commercial/Domestic) and
BLOCK system.
l
Commercial/Domestic System -
The standard system can be set for either Commercial or
Domestic mode. In Commercial mode the setting modes appear as PARTGUARD A,
PARTGUARD B and FULL SET. In Domestic mode they appear as HOME, NIGHT and FULL SET.
(see p.2-1 for an explanation).
l
Block System
- The Verifier can also be subdivided into a Block system. Block C is a common
area and will not arm until both Block 1 and 2 are fully armed. This is typically used in office
complexes but can have domestic applications as well (see "System Expansion"). Verifier 24
allows for 2 separate blocks, Verifier 64 allows for 4.
l
On-board zones
- There are 8 on-board zone inputs provided, with a common terminal for
each zone pair. These inputs are dual End Of Line monitored loops, and use 1KOhm resistors
across the zone contacts.
l
Multiplex Data Line Connection
- A further 16 zones (56 on the Verifier 64) may be added to
the system by connecting Line Encoder Modules (LEMs), Input/Output modules or a
combination of both to the Multiplex Data Line.
l
Remote Keypads
- Up to 16 addressable Remote Keypad Displays may be connected to
the Multiplex Data Line.
l
True Split System
- The Verifier 24/64 boasts a TRUE two-way SPLIT system. This feature allows
each tenant the luxury of a completely independent system under the control of one
multiplex panel. True split implies that each tenant has their own RKD, access codes etc.
and is completely oblivious to the system functionality of the other split system. Either system
type may be assigned to a split, thus permitting various combinations such as
Split 1
=
Commercial,
Split 2
= Domestic ;
Split 1
= Block,
Split 2
= Commercial, etc. (see "System
Expansion").
l
16 Users
- In addition to the Engineer and Master User (s), the system allows up to 16 general
users to be defined (32 users on the
VERIFIER 64
). Each user is identified by name, and can
have a flexible level of access.
l
250 Event Log
- The system’s 250-event log (up to 500 on the
VERIFIER 64
) records each
event/action, user name, and is timed to the second.
Introduction
ii
Содержание Verifier 24
Страница 1: ...Installation Manual ISSUE SIX Verifier 24 64 VERIFIER QUIT Verifier...
Страница 2: ......
Страница 4: ......
Страница 10: ...Chapter One...
Страница 12: ...Fig 2 Control Panel P C B 1 2...
Страница 13: ...Fig 3 Control Panel Cabinet Diameter shown 1 3...
Страница 18: ...1 8...
Страница 19: ...1 9...
Страница 20: ...1 10...
Страница 21: ...Chapter Two...
Страница 22: ...2 1...
Страница 23: ...l l l l BLOCK 1 BLOCK 2 COMMON l l System Expansion System Expansion 2 2...
Страница 24: ...Fig 11 Split System Fig 10 Block System 2 3...
Страница 25: ...l l l l l l l l l System Expansion System Expansion 2 4...
Страница 28: ...Fig 14 Input LEM A LEM 2 7...
Страница 29: ...Fig 15 Output LEM C LEM System Expansion System Expansion 2 8...
Страница 32: ...2 11...
Страница 34: ...Fig 19 Trouble Indication via a relay Fig 20 Trouble Indication via first zone 2 13...
Страница 36: ...Chapter Three...
Страница 39: ...Engineer Menu 3 3...
Страница 41: ...Engineer Menu 3 5...
Страница 44: ...Engineer Menu 3 8...
Страница 46: ...Engineer Menu 3 10...
Страница 47: ...Engineer Menu 3 11...
Страница 50: ...Engineer Menu 3 14...
Страница 51: ...Engineer Menu 3 15...
Страница 52: ...Engineer Menu 3 16...
Страница 53: ...VERIFIER VERIFIER 64 64 ONLY ONLY Engineer Menu 3 17...
Страница 54: ...Engineer Menu 3 18...
Страница 56: ...X Engineer Menu 3 20...
Страница 57: ...Engineer Menu 3 21...
Страница 58: ...Chapter Four...
Страница 61: ...l l l NOTE Verifier 64 systems allow for a maximum of 500 events recorded User Menu 4 3...
Страница 62: ...User Menu 4 4...
Страница 63: ...On a split system Date Time may only be set by users on Split 1 User Menu 4 5...
Страница 64: ...User Menu 4 6...
Страница 65: ...NOTE Verifier 64 systems allow for up to 32 users with I installer and 2 master codes 1 per split User Menu 4 7...
Страница 66: ...User Menu 4 8...
Страница 67: ...User Menu 4 9...
Страница 68: ...User Menu 4 10...
Страница 69: ...l l l User Menu 4 11...
Страница 70: ...HOME PARTGUARDA User Menu 4 12...
Страница 71: ...NIGHT PARTGUARD B User Menu 4 13...
Страница 72: ...User Menu 4 14...
Страница 73: ...User Menu 4 15...
Страница 74: ...User Menu 4 16...
Страница 75: ...Chapter Five...
Страница 77: ...Attributes Local Attributes Local Inhibit Attributes Inhibit Attributes Inhibit 5 2...
Страница 78: ...l l l l l l l l Attributes None Attributes Inhibit Attributes Chime Inhibit Attributes None 5 3...
Страница 81: ...5 6...
Страница 82: ...Chapter Six...
Страница 85: ...Fig 24 Connectinga Eurocom Fig 25 Direct Connect to a PC 6 3...
Страница 86: ...Fig 26 Connectinga Filesaver 6 4...