Document ID: 33080000
Rev: C
Technical Support: 1-800-626-6912
Page 17
C
LEANING AND
D
ISINFECTING
P
EDICURE
E
QUIPMENT
These are recommended procedures for cleaning and disinfecting all types of pedicure equipment,
including whirlpool units, air-jetted basins, pipe-less and all non-whirlpool basins, sinks, bowls and
tubs. In all cases described below, we recommend using an EPA registered hospital liquid
disinfectant that the label claims is a bactericide, virucide and fungicide. Always record the time each
cleaning procedure is performed in a salon pedicure cleaning log, for your convenience, a sample
Cleaning and Disinfecting log sheet is located on page 18. A patron or state board representative
may request to see your pedicure spa cleaning log.
“Pipe-less” foot spas
- For units with footplates, impellers, impeller assemblies and propellers
A
FTER EVERY CLIENT
1. Drain all water from the basin.
2. Remove impeller, footplate and any other removable components according to the
manufacturer’s instructions.
3. Thoroughly scrub impeller, footplate and/or other components and the areas behind each with
a liquid soap and a clean, disinfected brush to remove all visible residue, then reinsert impeller,
footplate and/or other components.
4. Refill the basin with water and circulate the correct amount (read the label for mixing
instructions) of the EPA registered hospital disinfectant through the basin for ten minutes.
5. Drain, rinse and wipe dry with a clean paper towel.
A
T THE END OF EVERY DAY
1. Fill the basin with warm water and chelating detergent (cleansers designed for use in hard
water) and circulate the chelating detergent through the spa system for five to ten minutes
(follow manufacturer’s instructions). If excessive foaming occurs, discontinue circulation and
let soak for the remainder of the ten minutes.
2. Drain the soapy solution and rinse the basin.
3. Refill the basin with clean water and circulate the correct amount (read the label for mixing
instructions) of the EPA registered hospital disinfectant through the basin for ten minutes.
4. Drain, rinse and wipe dry with a clean paper towel.
A
T LEAST ONCE EACH WEEK
1. Do not drain the disinfectant solution - Turn off the unit and leave the disinfecting solution in
the unit overnight.
2. In the morning drain, rinse and wipe dry with a clean paper towel.
Содержание RINATO XL SPA
Страница 1: ......
Страница 21: ...Document ID 33080000 Rev C Technical Support 1 800 626 6912 Page 21 HISTORY AND NOTES...