background image

User Manual SnG Smoking Cabins

5

It is a matter of experience to determine when the product needs to be 
cleaned, since the nature and the degree of pollution depend strongly on 
the particular situation, humidity, intensity of use, etc. Nevertheless,
the filters should be cleaned, on average, two times a year.

WARNING

Polluted filters often contain dust and dirt particles that could 
be a health hazard when inhaled. When replacing the filter, 
always wear a reliable and approved facemask.

8.2.1 Removing the filters

• 

Switch off the unit by turning the main switch.

• 

Loosen the two bolts of the filterbar cover. Use a 5 mm hex key.

• 

Remove the cover at the frontside filtercompartment.

• 

Remove the filter (see 8.2.2 until 8.2.6)

8.2.2 

Remove the ash Container

• 

Take off the cover with ash container.

• 

Remove the ash container by pulling the container upwards.

8.2.3 

Remove the Pre-filter and electrostatic filter(s)

• 

The pre-filters will be packed together with the electrostatic filters in a 
transport box. 

• 

Carefully remove the two metal frames by pulling them towards you.

• 

Remove the pre-filters by tearing them out of the metal frame.

• 

Place the new/clean pre-filter into the metal frame. Use a screwdriver 
to guide it into the metal frame.

• 

Take out the electrostatic filters by pulling them towards you.

• 

Take the clean electrostatic filters out of the transport box, and place 
the dirty electrostatic filters with the pre-filters in the transport box.

8.2.4 

Remove the Media filter(s)

• 

The HEPA filter removes small and ultra-small sized particles that could 
not be captured by the electrostatic filters.

• 

Slide the HEPA filter out of the filter unit.

8.2.5 

Remove carbon filter(s)

• 

The carbon filters are located at the bottom of the filter compartment.

• 

One carbon filter et is a combination of three types of cassettes: 
- ACF 1 
- ACF 2 
- Gas oxidation filter

8.2.6 

Replace ashtray tube

• 

The exhaust hose prevents loss of smoke and odours escaping from the 
ashtray.

• 

The exhaust hose is located beneath the table top.

• 

Remove the ashtray tube using a screwdriver.

• 

Remove one end of the tube from the ashtray.

• 

Remove the other end from the filter compartment.

• 

Take a new clean tube and fit it into the hole in the ashtray and filter 
compartment.

8.2.7 Mounting the filters

• 

Mount the filters, removed earlier, in reverse order.

TROUBLESHOOTING

If the machine does not function (correctly), consult the checklist below to 
see if you may remedy the error yourself (*). Should this not be possible 
consult a qualified service engineer.

WARNING

First check whether the error is of a mechanical or electrical 
nature. The electric system can only be serviced or repaired by
qualified and authorised service engineers.

Always switch OFF the machine and disconnect the mains before carrying 
out any repairs. First read the repair instructions at the beginning of this 
manual.

A number of problems in the checklist below can also be 
caused by defects in the connected equipment. This manual 
only deals with problems and solutions directly related
to the machine itself.

Action

Every 2 weeks 
to 2 months

Every 3 
months

Every 6 
months

Every 12 
months

Clean the outside of the cabin with a mild detergent.

X

Clean the inside of the cabin; glass panels and outside filter bar

X

Clean the inside of the filter compartment thoroughly, 

each time the filters are renewed

X

Clean the metal profiles in which the ElektroMax filters are mounted

X

Clean the contact plates in the filter compartment.

X

Clean the wooden panels at the side and the back of the filter 
compartment. A suitable cleaning solution for this is Hakupur, 49/314

X

Replace the pre-filter (see 8.2.3)

X

Replace the e-filter (see 8.2.3)

X

Replace the Media/HEPA filter (see 8.2.4)

X

Replace the carbon filter (see 8.2.5)

X

Replace the Ash container (see 8.2.2)

X

Replace the Ash Tube (see 8.2.6)

X

Clean the inside of the air inlet to reduce the flow of unpleasant odours

X

Renew contact plates and profiles every 2-3 years.

MAKE SURE ALL PARTS ARE COMPLETELY DRY AFTER CLEANING!
ALWAYS USE ORIGINAL PARTS AND FILTERS

Maintenance table

Содержание SMOKE 'N GO

Страница 1: ...EN User manual SMOKE N GO Smoking cabins...

Страница 2: ...e maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the m...

Страница 3: ...iven Never change the order of the steps to perform Always keep the manual with the product Pictograms and instructions on the product The pictograms warnings and instructions attached to the product...

Страница 4: ...8000 cigarette ends per cabinet PLAZA DOUBLE PLAZA Power consumption with poster display without poster display Stand by Plaza 210 W 150 W In operation Plaza 480 W 420 W Stand by Double Plaza 420 W 30...

Страница 5: ...ping from the ashtray The exhaust hose is located beneath the table top Remove the ashtray tube using a screwdriver Remove one end of the tube from the ashtray Remove the other end from the filter com...

Страница 6: ...lters Machine makes a crackling sound short circuit Dirty E filters Cleaning detergent residue left on E filters Moist left on E filters 10 ORDERING SPARE PARTS For spare parts available for the machi...

Страница 7: ...5 EC The Low Voltage Directive is in conformity with the applicable requirements of the following documents EN 55014 1 2006 A1 2006 A2 2011 Conducted emission EN 55014 2 1997 A1 2001 A2 2008 AC 1997 R...

Страница 8: ...gn changes 06032020 0 Euromate enables people to breathe pure air For the improvement of indoor air quality we offer high quality contemporary products that effectively remove a broad range of polluta...

Отзывы: