INSTALLATION AND PREPARATIONS FOR USE
15
Electrical connection diagram
An approved suitable cable must be connected from the Consumer Unit (main fuse box) and be protected by
its own 32amp fuse or Micro Circuit Breaker (MCB). The electrician must provide a fused all pole switch,
which disconnects both the line (live) and neutral conductors with a contact seperation of at least 3,0 mm.
The fused switch should be fitted to the kitchen wall, above the worksurface and to the side of the hob, not
above it, in accordance with IEE regulations. Connect the fused switch to a junction box which should be
fitted on the wall about 61cm (24 inches) above floor level and behind the hob. The hob's power supply cable
can then be connected. Connect one end to the junction box and connect the other end to the hob's power
connection box which is located at the back of the hob. Remove the cover of the power connection box and
install the cable, in accordance with the connection diagram.
L
N
B
R
O
W
N
GREEN
B
L
U
E
3X1,5 mm , H05V V-F
power supply cable must be used.
The earth wire must be connected
to screw with symbol.
2
For the induction hob, the cable must be
H05VV-F 3X1,5 mm² 60227 IEC 53 ••.
You will find the connection diagram
shown on the bottom of your appliance.