Upgrading a SANbloc JBOD Array to a RAID Array
24
7
Install the battery backup unit as described below.
8
Re-attach the power cables and switch on the enclosure.
9
You can now configure your RAID system using the
Management Software supplied.
Installing the Battery
Backup Unit
The battery backup unit (BBU) for the RAID controller is
installed on the ACM unit (see Figure 2-2).
Figure 2-2 Location of Battery Backup Unit on ACM
Follow this procedure to install the Battery Backup Unit
(BBU):
1
Remove the ACM from the enclosure by loosening the two
ACM screws and using the handle, slide the ACM out of the
encloure.
2
Lay the ACM on a flat surface as in Figure 2-2 above.
3
Orient the BBU as shown (see Figure 2-3).
ACM Assembly
BBU goes here