00096441.DOCX, Version 1.0
34/44
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
The device is equipped with a lockable power input connector. Plug in the power cord and turn it to the right
until it locks. Plug the power cord into a grounded electrical outlet that matches the rated voltage of the
machine.
OPERATION
With the power switch, you can switch the device on and off.
After you connected the effect to the mains, the TMH XB-230 starts running. During the reset, the motors are
trimmed and the device is ready for use afterwards.
Stand-alone operation
In the stand-alone mode, the TMH XB-230 can be used without controller. Disconnect the TMH XB-230 from
the controller and call the internal program. Please refer to the instructions under Control Board.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.
Addressing
The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the TMH XB-230 will respond to the controller.
If you set, for example, the address to channel 17, the TMH XB-230 will use the channel 17 to 32 for control.
Please, be sure that you don’t have any overlapping channels in order to control each TMH XB-230 correctly
and independently from any other fixture on the DMX-chain.
If several TMH XB-230 are addressed similarly, they will work synchronically.
Now you can start operating the TMH XB-230 via your lighting controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is
no data received at the DMX-input, the display will flash.
This situation can occur if:
- the XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.