00020505.DOC, Version 1.2
23/47
After the machine starts heating up, the display below HEAT flashes. When the machine is ready for fogging,
the display shows "OK".
Via the Function key, you can move in the menu. Press the Function-key until the value of the desired
function starts flashing. Via the Up/Down-buttons, you can adjust the desired function values or change the
selection. In this way, you can adjust the functions of the smoke-machine the best way to the requirements
of the user. The individual functions are desribed in the following.
LCD-display
Function
MU
01-99 (minutes)
Adjust the interval between each fog emission
SE
01-99 (seconds)
Adjust the duration of each fog emission
Timer mode
VO
01 minimum - 10 maximum
Adjust the output volume
Manual mode
DE
01-99 (seconds)
Adjust the duration of each fog emission
Heating
phase
HEAT
flashing = heating phase
Ok = ready
Display of heating phase
Timer mode
By pressing the Timer-button, the device works with the adjusted settings (MU, SE and VO). The green LED
below the Timer-button shows that the Timer-function is activated. If you wish to deactivate the Timer-
function, press the Timer-button again.
Manual mode
By pressing the Output-button, the fog emission is immediately triggered with the duration adjusted under
"DE“. The Manual-mode is automaticall stopped after the duration you defined or by pressing the Output-
button again.
Continuous fogging
By pressing the Continuous-button, the device produces continued fog. The continued fog is only interrupted
by necessary heating pauses. The green LED below the Continuous-button shows that the Continuous-
function is activated. If you wish to deactivate the Continuous-function, press the Continuous-button again.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.
DMX-protocol
Channel 1 – Fog volume
DMX-value:
Volume (%)
0 - 255
Gradual adjustment of the fog volume from 0 to 100 %
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!