00049912.DOC, Version 1.4
25/28
Pixel 16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
DMX In
Power In
Address 001
DMX Out
Power Out
Addressing the device
Each device occupies 48 channels. To ensure that the control signals are properly directed to each device,
the device requires addressing. This is to be adjusted for every single device by changing the DIP-switches.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Controlling:
After having addressed all LED Pixel Panels, you may now start operating these via your lighting controller.
The LEDs of the device are separated into 16 pixels on the main panel (see graphic), which can be
individually controlled with the following DMX-protocol.
Depending upon the installation direction, the Pixel order is as follows:
Pixel order 1
Pixel order 2
Pixel 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DMX Out
Power Out
Address 001
DMX In
Power In
Note:
This device is designed for vertical connections.
DMX protocol
Channel
Attribute of the LED/Pixel Number:
CH 1
R1
CH 2
G1
CH 3
B1
CH 4
R2
CH 5
G2
CH 6
B2
CH 7
R3
CH 8
G3
CH 9
B3
CH 10
R4
CH 11
G4
CH 12
B4
CH 13
R5
CH 14
G5
CH 15
B5