00094464.DOC, Version 1.1
22/23
Controlling:
After having addressed EUROLITE LED PFE-120 3000K Profile Spot, you may now start operating it via
your lighting controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, the LC display lights up permanently.
If there is no data received at the DMX-input, the LC display will flash.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective,
- the cable or connector is defective or the signal wires are not properly connected with the input connector.
DMX-protocol
Channel 1 – Dimmer
: Increasing brightness
Value:
Function:
000 – 255
0 – 100%
Channel 2 – Strobe
: Increasing speed
Value :
Function:
000 – 009
No function
010 – 255
0 – 100 %
Channel 3 – Dimmer speed
(step response)
Value:
Function:
000 – 063
Dimmer speed 1
064 – 127
Dimmer speed 2
128 – 191
Dimmer speed 3
192 – 255
Dimmer speed 4
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!