Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
The device is equipped with a lockable power input connector. Plug in the power cord and turn it to the right
until it locks. Plug the power cord into a grounded electrical outlet that matches the rated voltage of the
machine.
OPERATION
After you connected the spot to the mains, the EUROLITE LED PFE-120 3000K Profile Spot starts running.
The LC display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP and
DOWN.
The device has two operating modes. It can be operated in stand-alone mode via the control board or in
DMX-controlled mode via any commercial DMX controller.
Control Board
The Control Board offers several features: you can easily set the starting address or run the desired program
in manual mode.
Enter the menu by pressing the MODE-button. Browse through the
menu by pressing UP or DOWN. Press ENTER in order to select the
desired menu. You can change the selection by pressing UP or
DOWN. Press ENTER in order to confirm. You can leave every mode
by pressing MODE. The functions provided are described in the
following sections.
LCD Display
Function
DMX512
Setting the DMX starting address from 001 - 512
Dimmer
Setting of the Dimmer brightness
Strobe
Setting the Strobe speed
- STAND ALONE-MODE
•
Dimmer
•
Strobe
•
Master / Slave
•
Focus
•
Zoom
-
DMX MODE
MODE ENTER DOWN UP