00073190, Version 1.0
16/18
The occupation of the connection-cables is as follows:
Cable Pin
International
Brown Live
L
Blue Neutral
N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
Select the desired mode via the Programs selector.
All On: all LEDs are on.
Sound Active: 4 program groups are run sound-active.
Auto: One program is played after another. The program speed can be adjusted via the Speed-Control.
Auto Fade: One program is faded after another. The program speed can be adjusted via the Speed-Control.
DMX-controlled operation
To be able to operate the curtain with a DMX controller, the DMX starting address must be set for the first
DMX channel. See addressing.
Channel
Value
Function
Remark
CH 7
0-255
(White) Green color dimming 0-100%
CH 6
0-255
(White) Blue color dimming 0-100%
CH 5
0-255
(White) Yellow color dimming 0-100%
CH 4
0-255
(White) Red color dimming 0-100%
21-255
Channel 4-7 speed adjust of flash
0-20
STOP
CH 3
CH 2
CH 1
21-255
Channel 1 speed adjust of function
0-20
OFF
241-255
Sound actived
181-240
Fade
121-180
Auto Shift
61-120
Flash
Dimming,Channel 3-7 are working,if value
More 61 then 3-7 channel are not working
0-60
Channel 1 value 61-240 speed adjust
But channel 4-7 are dimming