60003641_V_2_1.DOC
18/19
5.2 Installation on a trussing system
Fixation point
5 kg
Safety rope
Fixation point
5 kg
Safety rope
Vor Gebrauch Anleitung lesen. Gerät
vor Feuchtigkeit schützen! Gefahr eines
elektrischen Schlages, niemals das
Gerät öffnen! Im Geräteinnern befinden
sich keine zu wartenden Teile. Wartungs-
und Servicearbeiten nur durch autorisier-
ten Fachhandel! Sicherungsseile für
Lasten und Eigensicherung verwenden!
Beim Installieren der Leuchten Warnhin-
weise beachten!
Read user manual before use. Keep away
from moisture! Risk of electric shock,
never open the housing! There are no
serviceable parts inside the device. Main-
tenance and service operations only by
authorized dealers. Use safety-ropes for
loads and for device itself! Respect all
warnings when rigging the luminaires!
Typ/Type: AB-46
Spannungsversorgung/Power supply: 230 V AC, 50 Hz ~
Max. Gesamtleistung/Max. power output: 4600 W
Max. Gesamtstrom/Max. total current: 20 A
Max. Nennleistung/Kanal/Max. output/channel: 1150 W
Max. Nennstrom/Kanal/Max. current/channel: 5 A
Max. Tragfähigk./Aufnahmepunkt/Max. load/fixat. point: 5 kg
Max. verteilte Tragfähigkeit/Max. spaced braceload: 30 kg
Max. zentrale Tragfähigkeit/Max. centered braceload: 25 kg
Gewicht/Weight: 3.8 kg
Inspektionen/Inspections: 1/y
Max. Nutzungsdauer/Max. service life: 10 y
Baujahr/Year of construction: 2002
®
eurolite
MADE IN CHINA
UP
CH-1
Fixation point
5 kg
CH-2
CH-3
Fixation point
5 kg
CH-4
Pin-occupation
Pin 1: Channel 1
Pin 2: Channel 2
Pin 3: Channel 3
Pin 4: Channel 4
Pin 5: Neutral
Pin 6: Neutral
Max. centered
braceload: 25 kg
Caution:
Trussing installations may cause severe injuries when crashing down! If you have doubts
concerning the safety of a possible installation, do NOT install the trussing!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the
installation's weight.
For suspending crossbeams, Alu-Bars, etc. always use a minimum of two hooks.
Attach the upper fixation of a C-hook to the crossbeam and tighten the fixation screw. Attach the Alubar to
the lower fixation of a C-hook and tighten the fixation screw.
At the suspended part, always install a safety-rope that can hold at least 12 times the weight of the
installation. You must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the
attachment eyelet and over the trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw.
The trussing system must always be earthed!
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
5.3 Connections
5.3.1 Connection with the mains
Connect the device to the mains with the industrial plug.
The occupation of the connection-cables is as follows:
5.3.2 Outputs
Output is via 4 safety sockets.
Connect your loads via the output-sockets. The maximum load per channel is 1,150 W (resistive). Please
note that the maximum current must never be exceeded.