00113162.DOCX, Version 1.1
17/24
DESCRIPTION OF THE DEVICE
(1) Infrared sensor for the remote control
(2) Lens with WW LED
(3) Fixation screw
(4) Mounting brackets
(5) Power input
(6) Power feed-through output
(7) DMX input
(8) Display with operating buttons
(9) DMX output
(10) Safety eyelet
INSTALLATION
WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing down. Make sure
that the device is installed securely and cannot fall down. The installation must be carried out by
a specialist who is familiar with the hazards and the relevant regulations.
The device may be placed on the floor by unfolding the brackets or fastened to a truss or similar rigging
structure. The device must never be fixed swinging freely in the room.
1
The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
2
Block access below the work area and work from a stable platform when installing the device.
3
Use rigging hardware that is compatible with the structure and capable of bearing the weight of the
device. Please refer to the “Accessories” section for a list of suitable rigging hardware.
4
Secure the device with a safety bond or other secondary attachment. This secondary safety
attachment must be sufficiently dimensioned in accordance with the latest industrial safety
regulations and constructed in a way that no part of the installation can fall down if the main
attachment fails. An appropriate eyelet is mounted on the device for fixation of the safety rope.
Fasten the safety rope in such a way that, in the event of a fall, the maximum drop distance of the
device will not exceed 20 cm.
5
To align the device, release the fixation screws at the mounting bracket, adjust the desired
inclination angle and tighten the fixation screws.
6
After installation, the device requires inspections periodically to prevent the possibility of corrosion,
deformation and looseness.