EuroLite 50630290 Скачать руководство пользователя страница 9

00035874.DOC, Version 1.1

9/12

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.

Important:

Damages caused by the disregard of this user manual are not subject to warranty. The dealer
will not accept liability for any resulting defects or problems.

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it
on immediately. The arising condensation water might damage your device. Leave the device switched off
until it has reached room temperature.

DANGER TO LIFE!

The electric connection must only be carried out by a qualified electrician!

This device falls under protection-class I. Therefore it is essential that the yellow/green conductor gets
connected to earth. The electric connection must be carried out by a qualified employee.

Never let the power-cord come into contact with other cables! Handle the power-cord and all connections
with the mains with particular caution!

Make sure that the available voltage is not higher than stated on the rear panel.

Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the
power-cord from time to time.

Always disconnect from the mains, when the device is not in use or before cleaning it.

Please consider that damages caused by manual modifications to the device are not subject to warranty.

Keep away children and amateurs!

OPERATING DETERMINATIONS

This device is a fixed general purpose luminaire. This product is only allowed to be operated with an
alternating voltage of 230 V, 50 Hz and was designed for indoor use only.

Do not shake the device. Avoid brute force when installing or operating the device.

When choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!

The symbol 

- - -m

determines the minimum distance from lighted objects. The minimum distance

between light-output and the illuminated surface must be more than 0.1 meters.

Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.

Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!

Please use the original packaging if the device is to be transported.

Please consider that unauthorized modifications on the device are forbidden due to safety reasons!

Содержание 50630290

Страница 1: ...Copyright Nachdruck verboten Reproduction prohibited F r weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL LED Deko Wandleuchte...

Страница 2: ...ION 11 CLEANING AND MAINTENANCE 11 TECHNICAL SPECIFICATIONS 11 Diese Bedienungsanleitung gilt f r die Artikelnummern This user manual is valid for the article numbers 50630290 50630291 50630292 506302...

Страница 3: ...eise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie die LED Deko Wandleuchte aus der Verpackung Features Kunstvolle LED Wandleuchte zur Festeinstellung Alumi...

Страница 4: ...urch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Bea...

Страница 5: ...Werkstoff wie z B Holz Beton Gasbeton Mauersteine ab Deshalb muss das Befestigungsmaterial unbedingt auf den jeweiligen Werkstoff abgestimmt werden Erfragen Sie die passende D bel Schraubenkombinatio...

Страница 6: ...installation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein BEDIENUNG Wenn Sie das Ger t an die Spannungsversorgung angeschlossen haben nimmt das Ger...

Страница 7: ...10 m Ma e LxBxH 208 x 85 x 30 mm 136 x 85 x 30 mm Gewicht 0 71 kg 0 40 kg Version 50630320 327 50630340 347 Spannungsversorgung 230 V AC 50 Hz 230 V AC 50 Hz Gesamtanschlusswert max 10 W max 9 W Anza...

Страница 8: ...ou follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your LED wall fixure Features Attractive LED sconce for permanent installat...

Страница 9: ...imped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Please consider that damages...

Страница 10: ...on the material used at the installation area building material such as wood concrete gas concrete brick etc This is why the fixing material must be chosen to suit the wall material Always ask a spec...

Страница 11: ...NING AND MAINTENANCE Disconnect from mains before starting maintenance operation DANGER TO LIFE We recommend a frequent cleaning of the device Please use a soft lint free and moistened cloth Never use...

Страница 12: ...er 2 High Power Maximum ambient temperature Ta 45 C 45 C Max housing temperature TB steady state 60 C 60 C Minimum distance from flammable surfaces 0 50 m 0 50 m Minimum distance to lighted object 0 1...