background image

7

1.Aim the remote controller towards the receiver on the air-
   conditioner.
2.The remote controller should be within 8 meters away 
   from the receiver.
3.No obstacles between the remote controller and receiver.
4.Do not drop or throw the remote controller.
5.Do not put the remote controller under the forceful 
   sunrays or heating facilities and other heating sources.
6.Use two 7# batteries, do not use the electric batteries.
7.Take the batteries out of remote controller before stop its 
   using for long.
8.When the noise of transmitting signal can t be heard 
   indoor unit or the transmission symbol on the display 
   screen doesn t flare, batteries need be replaced.
9.If reset phenomenon occurs on pressing the button of the 
   remote controller, the electric quantity is deficient and 
   new batteries need to be substituted.
10.The waste battery should be disposed properly.

Attention

Содержание Quadro ACE-35CH-FY BIO

Страница 1: ...ACE 35CH FY BIO ...

Страница 2: ...allation and test operation 1 6 8 10 12 15 18 21 Installation service 9 CONTENTS Operation and maintenance Safety Precautions Notices for use Names of each part Clean and care Troubleshooting Note All the pictures in this manual are just schematic diagrams the actual is the standard ...

Страница 3: ...ience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Only for the AC with CE MARKING This appliance is not intended for use by persons including children with reduced physical s...

Страница 4: ...ng operating or with wet hands It may cause electric shock or fire NO Take care not let the remote control and the indoor unit watered or being too wet Otherwise it may cause short circuit even fire SET TEMPERA TURE 自动 自动 自动 制冷 制冷 制冷 除湿 除湿 除湿 制热 制热 制热 SET ON OFF MODE CLEAN SPEED SLEEP HEALTH STRONG SWING DUST FEELING FUNGUSPROOF SCREEN TIMER AUTO FAN COOL HIGH DRY MID HEAT LOW NO Don t pull the po...

Страница 5: ...d be cut in time to prevent the occurrence of danger The appliance shall be installed in accordance with national wiring regulations An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks Don t block air inlet or air outlet Otherwise the cooling or heating capacity will be weakened even cause system stop operating Please note whether the installed stand is...

Страница 6: ...information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposals at least free of charge Meaning of crossed ...

Страница 7: ... conditioner is not fitted with a supply cord and a plug an all pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3 0 mm The power supply circuit should have leakage protector and air switch of which the capacity should be more than1 5 times of the maximum current Appropriate adjustments of the setting temperature can prevent the waste of el...

Страница 8: ...ly decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed Notices for use 6 The conditions of unit can t normally run Within the temperature range provided in following table the air conditioner may stop running and other anomalies may arise When the temperature is too high the air conditioner may activate the automatic protection device ...

Страница 9: ...TTENTION If the equipment emissions cannot meet the technical requirement of IEC 61000 3 3 following Attention should be take care Attention This appliance can be connected only to a supply with system impedance no more than Zmax In case necessary please consult your supply authority for system impedance information Product Type Zmax Product Type Zmax ASTW H12L4 IQ 0 445 ASTW 24G4 AE 0 027 ASTW 12...

Страница 10: ...Panel Air inlet grille Air filter Air louver Air vent Air outlet Connecting pipe Drain hose Air inlet Air outlet Air outlet grille Outdoor unit Remoter controller Note All the pictures in this manual are just schematic diagrams the actual is the standard Names of each part 8 ...

Страница 11: ...ater under any circumstances Volatile liquids such as thinner or gasoline will damage the air conditioner housing therefore please clean the housing of air conditioner only with soft dry cloth and damp cloth moistened with neutral detergent In the course of the using pay attention to cleaning the filter regularly to prevent the covering of dust which may affect the effect If the service environmen...

Страница 12: ...n cover and lock the panel Clean and care Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or fire please contact the authorized service center and let the professionals conduct the maintenance and checking the following items prior to contacting for maintenance can save your time and money Caution Troubleshooting Maintain after use 1 Cut off the power so...

Страница 13: ...able odor If there is odor it may be due to accumulation of the odor in the environment Please clean the air filter or activate the cleaning function There is sound of running water during the running of air conditioner Sometimes the hissing sound of running water can be heard This is the sound of the flow of the refrigerant not a malfunction A slight click sound is heard at the of start up or shu...

Страница 14: ...ere natural conditions e g heavy lampblack strong sandy wind direct sunshine or high temperature heat sources Avoid places within the reach of children Shorten the connection between the indoor and outdoor units Select where it is easy to perform service and repair and where the ventilation good The outdoor unit shall not be installed in any way that could occupy an aisle stairway exit fire escape...

Страница 15: ...ipe water pipe lightning rod telephone line or a circuit poorly grounded to the earth The grounding wire is specially designed and shall not be used for other purpose nor shall it be fastened with a common tapping screw Grounding Requirements Requirements of the mounting structure The mounting rack must meet the relevant national or industrial standards in terms of strength with welding and connec...

Страница 16: ...eeve Others PC Drain pipe 1 5 Plastic Strap Pipe Protection Ring Luting putty NOTE All accessories shall be subject to actual packaging material and if there is any difference please understand Packing list of the indoor unit Packing list of the outdoor unit N0 Name 1 2 3 1 Indoor Unit Set Quantity 2 Remote Controller Batteries 7 PC PC 1 Instructions 4 Outdoor Unit Connecting pipe Packing list 1 N...

Страница 17: ...rm so as to prevent vibration 2 Use the type screw to fasten the peg board horizontally mount the peg board on the wall and ensure the lateral horizontal and longitudinal vertical 3 Pull the peg board by hand after the installation to confirm whether it is solid Space to the ceiling Space to the wall 20cm above Mounting plate Wall through Hole 15cm above 200cm above Space to the floor Pipe protect...

Страница 18: ...using 2 Connect the connecting pipe to the indoor unit Aim at the pipe center tighten the Taper nut with fingers and then tighten the Taper nut with a torque wrench and the direction is shown in diagram on the right The torque used is shown in the following table Drain pipe connection Spanner Indoor unit pipe Taper nut Torque wrench connecting pipe Wrap the Piping 1 Use the insulation sleeve to wr...

Страница 19: ...able is not provided connection is needed in accordance with the wiring diagram Connector If there is a connector connect it directly To Outdoor unit 1 2 N To Outdoor unit 4 1 L 5 3 2 N To Outdoor unit 4 1 L 5 3 2 N To Outdoor unit 1 2 N 4 5 constant speed Heat pump type To Outdoor unit L N S Variable speed Cooling Only Install Indoor Unit NOTE This manual is usually includes the wiring mode for t...

Страница 20: ...l the connection pipe When prolonging the piping extra amount of refrigerant must be added so that the operation and performance of the air conditioner will not be compromised Not needed 5M Piping length Amount of refrigerant to be added 5 15M CC 12000Btu CC 18000Btu 20g m 30g m Note This table is for reference only 665 710 420 280 430 280 Outdoor Unit Size of Shape W1 W2 H D mm A mm B mm Installa...

Страница 21: ...in its original place and fasten it with screws E parts cover 1 2 L N Wiring Connection Wiring diagram Connector If there is a connector connect it directly constant speed Heat pump type Variable speed Cooling Only 1 2 N 1 2 3 To Indoor unit To Indoor unit 1 2 N 4 5 To Indoor unit 5 3 4 1 2 To Indoor unit To Indoor unit 1 L 2 N 4 S NOTE This manual is usually includes the wiring mode for the diffe...

Страница 22: ...e hose manifold valve and vacuum pump 3 Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes and check that the compound vacuum gauge reads 0 1MPa 76cmHg 4 After applying vacuum fully open the stop valve with a hex wrench 5 Check that both indoor and outdoor connections are free of air leakage Pressure gauge Charge hose 76cmHg manifold valve Compound meter Handle...

Страница 23: ...on in each of the power signal and grounding wires 3 If the grounding wire of the air conditioner is securely grounded Installation Safety Check 1 If the installation is secure 2 If the water drain is smooth 3 If the wiring and piping are correctly installed 4 Check that no foreign matter or tools are left inside the unit Leak test of the refrigerant Depending on the installation method the follow...

Страница 24: ...G SWING DUST FEELING FUNGUSPROOF SCREEN TIMER AUTO FAN COOL HIGH DRY MID HEAT LOW AIR CONDITIONER REMOTE CONTROLLER INSTRUCTIONS Read this instructions carefully so that you can use the air conditioner safely and correctly Take good care of the instructions so that it can be referred to at any time ...

Страница 25: ...x batteries Night Luminous Function of Remote Controller Automatic operation mode Attention Buttons description 1 5 6 7 CONTENTS Cooling Heating operation mode 5 5 5 Fan operation mode Drying operation mode 6 6 ...

Страница 26: ...state of normal working it displays setting temperature While the feeling function is start it will display room temperature and under the state of timer mode it will display setting timer 3 STRONG button Only under the state of cooling or heating mode press this button the fan speed is adjusted to strong auto maticlly and the LCD displays high fan the strong function is started to reach the highe...

Страница 27: ...ter air conditioner turn on including mode temperature swing fan speed and etc The LCD will displays all your setting and keep it when the timer reach to the set time the air conditioner will be working according to your set automatically Setting the OFF timer time a When remote controller is at on state press TIMER button the LCD displays TIMER OFF and the timer time the range of setting time is ...

Страница 28: ...eration Note clean function can be set in parallel with time start function in this case time start function will be executed after clean function 10 MODE button AUTO COOL DRY HEAT FAN AUTO Remark cold wind type has no heating function Which enables you to select different operation mode after each pressing the operation mode will be changed It shows in the following display 11 SLEEP button 1 Pres...

Страница 29: ...ion and thus dispersing strange smell Note 1 This function has not been set in the factory You may freely set and cancel this function The setting method is under off status of the A C and the remote controller point the remote controller toward the A C and continuously press pushbutton FUNGUSPROOF for one time the buzzer keep beeping five times again after five times beep indicating that this fun...

Страница 30: ...cator is on the air conditioner starts to operate the automatic mode Press the button again the air conditioner stops Cooling Heating operation mode cold wind type has no heating function 1 Press the MODE button select the Cooling or Heating operation mode 2 Press the or button set the temperature temperature can be set at 1 difference range from 16 32 3 Press the SPEED button you can select fan s...

Страница 31: ...r starts to operate the automatic mode Press the button again the air conditioner stops Night Luminous Function of Remote Controller Only the remote controller with this function can be used For your convenient use of the remote controller in the darkness without any lighting this remote controller has blue background light and luminous pushbuttons No matter what you press on any of the pushbutton...

Страница 32: ...ies and other heating sources 6 Use two 7 batteries do not use the electric batteries 7 Take the batteries out of remote controller before stop its using for long 8 When the noise of transmitting signal can t be heard indoor unit or the transmission symbol on the display screen doesn t flare batteries need be replaced 9 If reset phenomenon occurs on pressing the button of the remote controller the...