46
i) Wind chill / heat index / indoor dew point
Repeatedly press the button (index) to display wind chill, heat index or indoor dewpoint.
The heat index is calculated only when the temperature is at least 27 °C.
Range
Warning
Meaning
27 - 32 °C / 80 - 90 °F
Caution
Exhaustion possible
33 - 40 °C / 91 - 105 °F
Extreme caution
Dehydration possible
41 - 54 °C / 106 - 129 °F
Danger
Exhaustion probable
≥ 55 °C / 130 °F
Extreme danger
High risk of dehydration and/or a heatstroke
j) Data of the past 24 hours
• The weather station automatically stores the data of the last 24 hours on the hour.
• To view the data, repeatedly press the HISTORY button. The PREVIOUS DATA indicator appears next to the time.
• The current values are displayed again if no button is pressed within 5 seconds.
k) MAX/MIN memory
• Press the MAX/MIN button display the maximum/minimum measured values in the following order:
Outdoor temperature → Outdoor humidity → Indoor temperature → Indoor humidity → Wind chill → Heat index
→ Dewpoint → Barometric pressure → Average wind speed → Gust of wind → Rainfall
• Press and hold the MAX/MIN button for 2 seconds to reset the MAX/MIN memory.
• The current values are displayed again if no button is pressed within 5 seconds.
The time stamp is shown in addition to the measured value .
l) Over-range alarm
• The over-range alarm serves as a warning of certain climatic conditions. As soon as the value set by you is
exceeded or deceeded, an alarm sounds and the LED indicator on the front of the weather station flashes. You can
set limits for the following parameters:
Parameters
Upper (HI) / lower (LO) limit
Outdoor temperature
HI + LO
Outdoor humidity
HI + LO
Indoor temperature
HI + LO
Indoor humidity
HI + LO
Wind speed
HI
Rainfall
HI (measurement period: current day starting at midnight)