14
9880021100-CU 30P VERONA PRO 040413040413
WARNING:
This appliance requires ground connection for your protection
against shock hazard and should be connected directly into a properly
grounded receptacle.
WARNING: DISCONNECT ELECTRICAL SUPPLY BEFORE
SERVICING THE APPLIANCE.
When the flexible cord has to be changed it is necessary to follow
the procedure hereafter described:
-Turn off main gas shut-off valve and disconnect electrical supply
-Pull out entire range from the counter.
-Disconnect gas supply connector from appliance gas manifold
-Open up connecting terminal block cover.
-Open flexible cord lock and loosen up old cord prongs from terminal block
-Connect new flexible cord prongs to terminal block and fix flexible cord lock,
remember earth wire, yellow and green, must be longer by one inch that the
other ones. For Line and Neutral wire connection, follow signs on terminal
block.
-The flexible cord must be hold tight by the cord lock, in such a way that it
may not pulled out. The flexible cord path must not be in proximity or in
contact with hot surfaces that may damage the cord itself.
ATTENTION: the flexible cord must be in accordance with National
Electrical Codes and suitable for the hob technical characteristics
electrical ratings. A 18 AWG three-prong grounding plug flexible cord,
type SJT 3x18 AWG.
THE MANUFACTURES DECLINE ANY RESPONSIBILITY FOR IMPROPER
INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE,
MAINTENANCE OR USE OF RANGE WHICH CAN RESULT IN SERIOUS
INJURY OR PROPERTY DAMAGE.
Содержание verona pro VEFSGG30
Страница 22: ...22 9880021100 CU 30P VERONA PRO 040413040413 Fig n 11 Fig n 12 ...
Страница 23: ...23 9880021100 CU 30P VERONA PRO 040413040413 Fig n 13 Fig n 14 ...
Страница 24: ...24 9880021100 CU 30P VERONA PRO 040413040413 Fig n 15 Fig n 16 ...
Страница 25: ...25 9880021100 CU 30P VERONA PRO 040413040413 Fig n 17 Fig n 18 A Fig n 18 B Fig n 19 ...