TROUBLESHOOTING 

Error type                            Check                                                Action                                                     

The Info Pod cannot be raised 
or lowered 

Is the plug in the socket and the power turned 
on? 

Check the electric power, e.g. try to 
connect a lamp to check that the main 
supply is working. 

Is there any visible damage to wires, 
operating units or columns? 

Any damaged parts should be 
replaced, contact customer service for 
new parts. 

Is the control or control box faulty? 

Check all the connections. Check that 
the main plug is in the socket. Connect 
a control that you know is serviceable. 
If this works, the first control is faulty. 
Replace the faulty unit and check that it 
functions correctly. 

Is there a loose connection between the 
control box and the column(s)? 

Has the main cable fallen out? 

The Info Pod works only in 
one direction 

Has the Info Pod reached the max./min. 
position? 

The Info Pod only works between the 
programmed positions 

Is there too much load on the Info Pod 
compared to the max. weight? 

Remove the additional weight 

 and 

try again 

Is the desk more heavily loaded than it was 
when it last functioned normally? 

The Info Pod is not raised to 
full height. It stops at the same 
height each time.

 

 

The system has coded a new end stop. 
Reset the program to remove the new 
end stop. 

The Info Pod does not go to 
max. position 

 and stops 

in the wrong position

 

 

Reset the program. 

The Info Pod only goes down, 
even though it is not 
overloaded

 

Only some of the colums 
retract when the Info Pod is 
lowered 

Either the column or columns that fail to 
retract is/are faulty or the cable connection to 
the columns(s) is faulty. 

Replace cable. If this doesn’t help, 

replace the column. 

The table is fully lowered and 

won’t lift. I cannot see if all the 

columns are moving. 

The desk is overloaded. 

Remove some of the load from the Info 
Pod. 

Either one or more columns is/are faulty or 
the cable connection between column(s) and 
control box is faulty. 

Contact electrician for support. 

 

 

RESETTING THE PROGRAM 

 

Press the

      

button until the Info Pod is in bottom position. 

 

Release button. 

 

Press the  

     

button again (4-5 sec.) and then release the button again.  

 

The Info Pod is now reset.  

 

 

Содержание Info Pod E4383

Страница 1: ...User Manual Info Pod E4383 E4384...

Страница 2: ...laration of conformity Congratulations with your new Info Pod The height adjustable Info Pod is ideal for large and small libraries as an information point search station or reception pod Please read...

Страница 3: ...on adjustable feet To prevent accidents always lock the position of the info pod by using the adjustable feet Do not place the Info Pod in front of emergency exits or in a humid environment To use the...

Страница 4: ...or electric shock Electrical products may due to short cables when moving the table top fall off the table It is prohibited to use the Info Pod as a climbing aid as the added weight could be too heavy...

Страница 5: ...lectronics recycling Height adjustable counters are not covered by the Waste Electrical and Electronic Equipment Directive WEEE WARRANTY The product is covered by our 2 year warranty for material and...

Страница 6: ...d to the max weight Remove the additional weight and try again Is the desk more heavily loaded than it was when it last functioned normally The Info Pod is not raised to full height It stops at the sa...

Страница 7: ...User Manual Info Pod E4383 E4384 7 www eurobib com EU DECLARATION OF CONFORMITY...

Страница 8: ...w bseurobib no GERMANY Schulz Speyer Bibliothekstechnik AG Friedrich Ebert Stra e 2a 67346 Speyer sales schulzspeyer de www schulzspeyer de FRANCE BC Interieur S A R I 8 All e Lorentz 77 420 Champs su...

Отзывы: