background image

5) GAS CONNECTION

The gas connection is located in the rear and on the

underside of the appliance 100 mm from the right

hand side.

There are two ways to carry out the connection to

the main gas line:

A. 

The hotplate can be connected with rigid pipe as

specified in AS5601 table 3.1.

B. 

If installing with a hose assembly, install with a

hose assembly that complies with AS/ANZ 1869

(AGA Approved), 10mm ID, class B or D, no more

than 1.2m long and in accordance with AS5601.

Ensure that the hose does not contact the hot

surfaces of the hotplate, oven, dishwasher or any

other appliance that may be installed underneath or

next to the hotplate. The hose should not be

subjected to abrasion, kinking or permanent

deformation and should be able to be inspected

along its entire length with the cooktop in the

installed position.

Unions compatible with the hose fittings must be

used and all connections tested for gas leaks.

The gas supply connection for the hose assembly

must be accessible.

Natural Gas

Natural Gas installations require the connection of

a gas regulator at the appliance. This regulator is

supplied with the appliance on purchase.

Assemble the regulator (noting the gas flow

direction) and transition pieces (supplied with the

appliance), in accordance with figure 11.

The transition piece on the supply side of the

regulator must be provided by the installer.

Liquified Petroleum Gas

In a LPG installation the gas regulation is made at

the gas cylinder and regulation at the appliance is

not required. To connect supply to the appliance

use transition pieces as shown in figure 12. These

pieces  are  supplied  with  the  appliance  on

purchase.

WARNING:

THE BURNER FLAME MUST BE ADJUSTED BY

THE INSTALLER.

FAULTY  INSTALLATION  WILL  NOT  BE

COVERED UNDER WARRANTY.

THE  APPLIANCE  IS  FACTORY  SET  FOR

NATURAL GAS. THE TEST POINT PRESSURE

SHOULD BE ADJUSTED TO 1.00kPa WITH THE

WOK BURNER OPERATING AT MAXIMUM.

INSTALLATION

FIG. 11

FIG. 12

7

Содержание EGZ90FCTSX

Страница 1: ...op requires service please contact your local customer service centre or your nearest Eurostyle agent listed at the back of this booklet COD 04017HM 11 05 2012 Dear Customer Thank you for purchasing a...

Страница 2: ...rivet 2 burners 8 Central U rapid burner Wok trivet 9 Central fish trivet 10 Burner 1 control knob 11 Burner 2 control knob 12 Burner 3 control knob left back 13 Burner 3 control knob right back 14 Bu...

Страница 3: ...ion small flame fig 1 Always place a lid on the pans Burners Power ratings Pan in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 24 26 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 A...

Страница 4: ...ouch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting from improper incorrect or unreasonable use During and...

Страница 5: ...Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To optimize the appear...

Страница 6: ...st be a suitable non combustible material for a height of 150 mm for the entire length of the hob Any combustible construction above the hotplate must be at least 600 mm above the construction above t...

Страница 7: ...be used and all connections tested for gas leaks The gas supply connection for the hose assembly must be accessible Natural Gas Natural Gas installations require the connection of a gas regulator at...

Страница 8: ...the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspond...

Страница 9: ...liance falls to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type a...

Страница 10: ...bel adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 1 Remove each burner cap and burner ski...

Страница 11: ...ad of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the autho...

Страница 12: ...p is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the ta...

Страница 13: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Страница 14: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Страница 15: ...15...

Страница 16: ...16...

Отзывы: