25
Indoor Unit AWR512HL
Outdoor Unit AER512SH
240V Single Phase 50Hz
RATING CAPACITY 3.35 kW
AIR FLOW RATE 490 m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 20 25 30 35 40 45
TC 3.38 3.23 3.08 2.93 2.76 2.54
CM 0.96 1.04 1.11 1.19 1.30 1.42
21 SHC 2.22 2.14 2.06 1.99 1.90 1.79
15 23 SHC 2.46 2.38 2.31 2.23 2.14 2.03
25 SHC 2.71 2.63 2.55 2.47 2.38 2.27
27 SHC 2.95 2.87 2.79 2.71 2.62 2.51
29 SHC 3.19 3.11 3.03 2.93 2.76 2.54
31 SHC 3.38 3.23 3.08 2.93 2.76 2.54
TC 3.62 3.46 3.31 3.15 2.96 2.72
CM 0.98 1.06 1.14 1.22 1.34 1.45
21 SHC 1.98 1.90 1.82 1.74 1.65 1.54
17 23 SHC 2.22 2.14 2.06 1.98 1.89 1.78
25 SHC 2.46 2.38 2.30 2.22 2.13 2.02
27 SHC 2.70 2.62 2.54 2.46 2.37 2.26
29 SHC 2.94 2.86 2.78 2.70 2.61 2.50
31 SHC 3.18 3.10 3.02 2.95 2.85 2.72
TC 3.85 3.69 3.52 # 3.35 3.15 2.90
CM 1.01 1.10 1.17 1.26 1.38 1.49
21 SHC 1.72 1.64 1.56 1.48 1.39 1.28
19 23 SHC 1.96 1.88 1.80 1.72 1.63 1.52
25 SHC 2.20 2.12 2.04 1.96 1.87 1.76
27 SHC 2.44 2.36 2.28 2.20 2.11 2.00
29 SHC 2.68 2.60 2.52 2.44 2.35 2.24
31 SHC 2.92 2.84 2.76 2.68 2.59 2.48
TC 4.08 3.91 3.73 3.55 3.34 3.07
CM 1.04 1.13 1.21 1.30 1.41 1.53
23 SHC 1.69 1.61 1.53 1.46 1.37 1.26
21 25 SHC 1.93 1.85 1.77 1.70 1.61 1.50
27 SHC 2.17 2.09 2.02 1.94 1.85 1.74
29 SHC 2.41 2.33 2.26 2.18 2.09 1.98
31 SHC 2.65 2.57 2.50 2.42 2.33 2.22
TC 4.33 4.15 3.95 3.73 3.49 3.25
CM 1.06 1.16 1.24 1.33 1.45 1.57
23 25 SHC 1.65 1.57 1.49 1.40 1.31 1.22
27 SHC 1.89 1.81 1.73 1.65 1.55 1.46
29 SHC 2.13 2.05 1.97 1.89 1.79 1.70
31 SHC 2.37 2.29 2.21 2.13 2.04 1.94
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.