![Euresys Coaxlink Series Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/euresys/coaxlink-series/coaxlink-series_programmers-manual_2436137055.webp)
55
Info command
Numerical identifier used to query a specific piece of information from a GenTL module. Info
commands are defined either in the
, or in a vendor-specific header
file (e.g., info commands specific to Coaxlink are defined in
include/GenTL_v1_5_
EuresysCustom.h
).
Interface module
GenTL module that represents a frame grabber.
Parent of the device module.
I/O toolbox
Part of Coaxlink card that controls digital I/O lines and implements tools such as rate
converters, delay lines, etc.
Hosted in the interface module.
Register description
XML file mapping low-level hardware registers to camera or frame grabber features.
Remote device
Camera connected to a frame grabber.
The term
remote
is used to distinguish this from the GenTL device module.
System
GenTL module that represents the GenTL producer.
Also known as TLSystem.
Parent of the interface module.
Timestamp
The time at which an event occurs.
For Coaxlink, timestamps are always 64-bit integers and are expressed as the number of
microseconds that have elapsed since the computer was started.
9. Definitions
Coaxlink