background image

Note: Storage Tank of this product must be periodically (at least once in every 30 days) cleaned by a 

disinfectant. Disinfection Tablets may be purchased from the Company authorized Service Centre. 

Please  follow  the  disinfection  process  strictly  as  per  the  instructions  as  provided  in  this  User 

Manual. 

1. 

Switch Off the power supply to the 

purifier 

when the tank is full. Stop the water supply to the unit 

(by removing the raw water inlet pipe from the Diverter Valve). Remove the top cover of the 

purifier 

unit. 

2.   Disengage the pure water inlet pipe of storage tank (shown in the pics.) 
3.   Drop one disinfection tablet into the opening of the inlet connector of tank. CAUTION : Keep 

away the disinfection tablets out of reach of children. Do not eat/consume this disinfection tablet. 

4.   Snug 

fit 

the pipe and leave the unit for 30 min. 

5.  

After 30 min. open the faucet and discard the 

purifier 

tank water completely. CAUTION: Do not 

drink this water. Check if the tablets has completely dissolved. If not, then discard the leftover pcs. 

of tablet. 

6.   Switch On the power to the unit and insert back the raw water inlet pipe into the diverter valve as it 

was before. 

7. 

Let the 

purifier 

tank get completely 

filled. 

Discard this 

fill 

too. 

8. 

Allow the tank to get 

filled 

again. Now your Smart Plus RO+ UV+MTDS  is ready for use. You can 

start using this water. in case you notice any medicinal taste/smell then discard the water and let it 

refill 

again. 

9. 

Please ensure that this disinfection process is carried out by the authorized installation person / 

service technician during 

first 

installation and in every subsequent mandatory servicing of your 

product.  

1000