System 5-B Digital Audio Mixing System Operation Manual
eMix Application
41
Figure 4-9 shows the lower part of the Console I/O window. The
Selected:
area shows
the sources and destinations for the
A Input
and
B Input
cells selected above. The
numbered tabs (1–48 etc.) display additional pages of patchpoints. The four buttons on
the right of Figure 4-9 perform the following functions:
•
Patch
:
Makes a connection between selected patchpoints
•
Unpatch
: Breaks the connection between selected patchpoints
•
Clear
:
Deselects selected patchpoints
•
View Log
: Shows a log of failed patches
Figure 4-9
Bottom of Console I/O window
4.2.2
Device Inputs and Outputs
There are up to 12 MADI device input/output ports on the console, each carrying up to
56 channels (44.1/48 kHz) or 28 channels (96 kHz).
NOTE:
To clarify the use of the terms
Inputs
and
Outputs
in PatchNet,
Device
per-
tains to equipment other than the System 5-B console. Therefore,
Device In-
puts
refers to
inputs to an external device
, not the console.
4.2.3
Cabling
This category handles MADI cable connections for the ML530 Mic/Line Interfaces.
Mic/Line Interface Patching
For mic inputs and analog inputs not at +4 dB, the Euphonix ML530 provides 24
preamps each with gain, phantom power, high-pass filter, and hiZ/loZ switching. The
analog outputs are connected to an AM713 Analog to MADI converter which then con-
nects to one of the MADI inputs on the SH612 Studio Hub.
Содержание System 5B
Страница 14: ...System 5 B Digital Audio Mixing System Operation Manual xiv...
Страница 16: ......
Страница 24: ...System 5 B Digital Audio Mixing System Operation Manual New Features in Version 2 8 1 24...
Страница 54: ...System 5 B Digital Audio Mixing System Operation Manual eMix Application 54...
Страница 74: ...System 5 B Digital Audio Mixing System Operation Manual CM401 Master Section 74...
Страница 152: ...System 5 B Digital Audio Mixing System Operation Manual GPI O Event System 152...
Страница 156: ...System 5 B Digital Audio Mixing System Operation Manual 156...