background image

EUM/OPS/MAN/13/730927 

v3F e-signed, 15 April 2016 

Ayecka SR1 DVB Receiver EUMETCast Setup Guide 

 

 

Page 2 of 36 

 

Page intentionally left blank

 

Содержание Ayecka SR1

Страница 1: ...perty of EUMETSAT Doc No EUM OPS MAN 13 730927 Issue v3F e signed Date 15 April 2016 WBS DBS Ayecka SR1 DVB Receiver EUMETCast Setup Guide EUMETSAT Eumetsat Allee 1 D 64295 Darmstadt Germany Tel 49 61...

Страница 2: ...EUM OPS MAN 13 730927 v3F e signed 15 April 2016 Ayecka SR1 DVB Receiver EUMETCast Setup Guide Page 2 of 36 Page intentionally left blank...

Страница 3: ...Conf Windows Routing Conf note of current firmware RX2 non support v3 15 December 2014 Links Updated Added C Band Configuration Removed DVB S Ku Band Configuration v3A 12 January 2015 Added Software u...

Страница 4: ...ameters for DVB S2 Ku Band Reception 12 4 5 2 1 Configuration 12 4 5 2 2 Disable High Volume Service 13 4 5 2 3 RX Link Margin Thresholds 14 4 5 2 4 Verify Lock and quality for DVB S2 Ku Band 16 4 5 3...

Страница 5: ...on in Africa and SES 6 for DVB S C band reception in S America An EKU has been obtained from the EUMETSAT user help desk The reception host has the latest EUMETCast reception software installed The Ay...

Страница 6: ...ll turn red again Green The led turns green constantly after two conditions are met The SR1 application software has been successfully launched AND The Firmware has been successfully programmed 3 2 Sa...

Страница 7: ...terface using Serial over USB to use the Serial over USB you must install the Virtual Com drivers on the Client PC Before proceedings with the installation of the receiver install the appropriate Seri...

Страница 8: ...tomatic Configuration of SR1 A utility SR1CFG can be used to automatically perform the initial setup of the Ayecka SR1 receiver to allow it to receive the EUMETCast Ku Band DVB S2 EUMETCast C Band DVB...

Страница 9: ...matic configuration is taking too long more than 5 minutes stop SR1CFG unplug the receiver from power plug it back and run SR1CFG exe again The applied configuration using SR1CFG exe may sometimes dif...

Страница 10: ...receiver To configure the receiver you can use putty or any other Windows HyperTerminal in our example below putty is used it can be downloaded from www putty org Configure a Serial connection as fol...

Страница 11: ...The network configuration parameters are shown as follow see table below Network 1 Management IP Address 192 168 10 99 2 Management IP Mask 255 255 255 0 3 Management Ethernet Address CC F6 7A 04 CA B...

Страница 12: ...000 MHz 3 Standard DVB S2 4 Coding Mode VCM 5 Symbol Rate Auto 6 MODCOD Auto 7 RollOff Auto 8 Pilot Auto 9 Spectral Inversion Auto A Gold Code 0 B Frame Type Auto C Encapsulation MPEG TS D ISI 1 E Fil...

Страница 13: ...x1 and 0 for Rx2 this will bring 8 PIDs to the list In this mode when changing Rx in due to loss of RF lock on one the 8 PIDS configuration follows the other Rx Number of Transport Filters per Channel...

Страница 14: ...r Upgrade G RX Link Margin Thresholds H MODCODS Filter 0x00001000 Note This is a bit mask and the settings for the EUMETCast services are Service required MODCOD MODCOD mask Displays as Basic Service...

Страница 15: ...3 Restore Factory Defaults and Reset 4 Telnet 5 NTP Server IP Address 0 0 0 0 6 SNMP Trap Server IP Address 0 0 0 0 7 SNMP Read Community public 8 SNMP Write Community private 9 Events Configuration...

Страница 16: ...1 Tuner Status Locked 2 Demodulator Status Locked 3 Transport Status Locked 4 Demodulator Frequency Offset 1184 KHz 5 Demodulator Es N0 11 1 dB 6 Signal Input Level 39 0 dBm 7 Demodulator BER 0 00 e 7...

Страница 17: ...atus Active J Profile Name EUMETCast C Band Africa K DiSEqC Switch Control Error L DiSEqC General Command 0x0 Then to set the Filters Table choose E Filters Table For each PID required select slot num...

Страница 18: ...eplacing the non active image Notes 1 The SW release upgrade may delete the current configuration Please make sure you have the original EUMETSAT configuration of the SR1 prior to upgrade 2 Telnet and...

Страница 19: ...etup Guide Page 19 of 36 7 Check that the IP Server Interfaces is 192 168 10 105 8 Click on Browse to select the directory that you have download the new software and click OK 9 Click on Show Dir to c...

Страница 20: ...m Reset 2 Cold Reset 3 Restore Factory Defaults and Reset 4 Telnet 5 NTP Server IP Address 0 0 0 0 6 SNMP Trap Server IP Address 0 0 0 0 7 SNMP Read Community public 8 SNMP Write Community private 9 E...

Страница 21: ...Seconds And on the Tftpd32 screen the IP adress of the SR1 management port in this example 192 168 10 99 and the update file 16 Upon finished restart the Sr1 device 17 After reboot connect again to th...

Страница 22: ...efaults and Reset 4 Telnet 5 NTP Server IP Address 0 0 0 0 6 SNMP Trap Server IP Address 0 0 0 0 7 SNMP Read Community public 8 SNMP Write Community private 9 Events Configuration A Software Upgrade B...

Страница 23: ...b To run Ayecka Web Interface on your Windows machine you need to run server software on your computer To download and install the recommended server software follow the following instructions step by...

Страница 24: ...k Go This action will create new data base for Ayecka system 5 Click Ayecka from the left databases list 6 Select Import in the top menu Select Insert_tables sql file from Mysql directory and click Go...

Страница 25: ...an either run Sr1Control jar directly or use the sample command script suitable edited although that should not be necessary SR1 Console Utility Interface In order to configure the SR1 Controller left...

Страница 26: ...e device Software Update Support Dump That creates a SupportDump txt file with the following info Software Version 1 05b255 Hardware Version 2 00 FPGA Version 2 02b922 RX1 LNB power 2 permanentStorage...

Страница 27: ...15 April 2016 Ayecka SR1 DVB Receiver EUMETCast Setup Guide Page 27 of 36 RX1 22K 0 SN 111700 RX1 FreqOffset 1237 RX1 BER 0 Active RX 1 RX1 SR 32995947 RX1 Power Level 220 RX1 Esno 120 Rx1 Tuner statu...

Страница 28: ...ori 8 2 Firewall Make sure the firewall allows traffic from the interface address in 6 1 8 3 Windows Routing Table If the TelliCast fails to work being either stuck in the yellow T icon state or if th...

Страница 29: ...unrestricted multicast from network interfaces under Linux reception host login as root and update if needed the sysctl parameters as follow vi etc sysctl conf net ipv4 conf default rp_filter 0 net ip...

Страница 30: ...teway 0 0 0 0 8 Management DHCP Client Determine if Management interface IP address is static or DHCP ON if exists else OFF It must be set to OFF it a fixed mgmt IP has to be set 9 Management Port Sta...

Страница 31: ...ve the data packets from SR1 the traffic LAN port of the SR1 must be connected to the reception host default setting J Isolate Networks Isolated or the management port of the SR1 J Isolate Networks Co...

Страница 32: ...reception host must have a LAN GigE interface The LAN Multicast is enabled One of the reception host NICs is set to a static IP 192 168 10 103 Into recv ini interface_address 192 168 10 103 Management...

Страница 33: ...ed to automatically obtain the IP and the interface_address into recv ini is not specified dropped or commented the Tellicast will look for all the available network interfaces on the host and catch t...

Страница 34: ...AN GigE interface 1000BaseT IP Dynamic EUMETCast reception host DHCP Server LAN and Mgmt Multicast ON Networks connected Traffic and Mgmt DHCP ON Switch Or Management Interface 100baseT NIC IP Dynamic...

Страница 35: ...Ayecka SR1 DVB Receiver EUMETCast Setup Guide Page 35 of 36 9 2 3 SR1 as Switch SR1 can be used as switch to connect the reception host to other hosts DHCP server LAN The Traffic and Mgmt Multicast ar...

Страница 36: ...icast lost connection to announcement channel losses a Misconfigured recv ini file check IP address is correct b Problem with gigabit interface Try using 100Mbit on host NIC c Mis configured PIDs on D...

Отзывы: