Operating Instructions
Safety Switches NP...
6
Subject to technical modifications; no r
esponsibility is accepted for the accuracy of this information.
© EUCHNER GmbH + Co. KG
083684
-07
-10/15 (translation of the original operating instructions)
Figure 6: Minimum door radii
Actuator
Door radius min.
[mm]
Actuator P-G…
1000
Actuator P-W…
1000
Hinged actuator P-OU…
90
Hinged actuator P-LR…
100
Hinged actuator P-LR/P-LRN
R > 10
0
Hinged actuator P-OU/P-OUN
12
26
20
35
28
+2
R > 90
Figure 5: Dimension drawing NP…
Necessary minimum permissible overtravel
Approach direction
Standard actuator
Overtravel actuator
Horizontal (h)
28 + 2
28 + 7
Vertical (v)
29.5 + 1.5
29.5 + 7
Only with adapter NP-K
Order actuator separately
Figure 4: Switching elements and switching functions
21
22
13
14
22
21
2
1
4
3
2
1
11
12
22
21
2
1
4
3
618
628
638
Terminal assignment
with plug connector SR6
Connector illustration
Plug connector SR6
View of safety switch connection side
Switching element Switching contacts
628
1 NC c
1 NO contact
638
2 NC contacts
648
2 NC co
1 NO contact
v
h
21
22
21
22
21
22
21
22
21
22
21
22
13
14
13
14
11
12
11
12
31
32
31
32
21
22
21
22
13
14
13
14
Safety guard closed
Safety guard open
618
1 NC contact
1
4
3
2
12
11
2
1
4
22
21
638
3
1
4
3
2
12
11
2
1
4
22
21
638
3
Terminal assignment
with plug connector M12
Connector illustration
Plug connector M12
View of safety switch connection side
M20 x 1,5
M20 x 1,5
M4 (2x)
NP1-…AS
NP1-…AB
NP.-… with adapter NP-K
NP2-… with plug connector SR6
M12x1
NP3-… with plug connector SM4 (M12)
Built-in connector not aligned