7
2530674-02-03/21 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB2-I-BP.-… / MGB2-I-BR.-…
EN
2.1. Main differences, MGB2-BP and MGB2-BR
System family
Symbol
Use
MGB2-BP
BP
Optimized for operation in safe control systems.
If series connection is not necessary, the number of terminals required can be reduced using this system family.
MGB2-BR
BR
Linking of several guards on one shutdown path. As a consequence, several safety doors can be very simply polled using one evalua-
tion unit or two control system inputs.
3. Description of the safety function
Devices from this series feature the following safety functions:
Monitoring of the guard position
(interlocking device according to EN ISO 14119)
Ì
Safety function: The safety outputs are switched off when the guard is open (see chapter
Ì
Safety characteristics: category, Performance Level, PFHD (see chapter
).
The following applies to devices with emergency stop:
Emergency stop
(emergency stop device according to EN ISO 13850)
Ì
Safety function: emergency stop function
Ì
Safety characteristics: B
10D
value (see chapter
4. Exclusion of liability and warranty
In case of failure to comply with the conditions for correct use stated above, or if the safety regulations are not followed,
or if any servicing is not performed as required, liability will be excluded and the warranty void.