Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
34
(translation of the original operating instructions) 112657-12-01/15
14.2. MGB-AR system status table
Operating mode
Safety outputs FI1A
and FI1B
Door position
Position of the bolt
tongue
Safety outputs FO1A
and FO1B
Door monitoring output
(OD)
Bolt tongue monitoring
output (OT)
Diagnostics monitoring
output (OI)
LED indicator
State
Power (green)
STATE (gr
een)
DIA (red)
Self-test
X
X
X
OFF
OFF
OFF
OFF
5 Hz
Self-test after power up
Normal opera
-
tion
X
open
not inser
ted
OFF
OFF
OFF
OFF
Long OFF shor
t ON
Normal operation, door open
X
closed
not inser
ted
OFF
ON
OFF
OFF
Long ON, shor
t OFF
Normal operation, door closed
OFF
closed
inser
ted
OFF
ON
ON
OFF
Long ON, shor
t OFF
Normal operation, door closed, bolt tongue inser
ted safety inputs FI1A/FI1B OFF
ON
closed
inser
ted
ON
ON
ON
OFF
Normal operation, door closed, bolt tongue inser
ted. Safety inputs FI1A/FI1B ar
e ON. Safety outputs FO1A and FO1B ar
e ON
OFF
closed
inser
ted
OFF
ON
ON
OFF
Long ON, shor
t OFF
Operation in an AR chain:
Normal operation, door closed and locked. Safety outputs on the pr
evious device OFF
ON
closed
inser
ted
ON
ON
ON
OFF
Operation as separate device:
Normal operation, door closed and locked.
Operation in an AR chain:
Normal operation, door closed and locked. Safety outputs on the pr
evious device ON
Teach-in standby
(only for MGB unicode)
X
open
not inser
ted
OFF
OFF
OFF
OFF
3 x
Door open; device is r
eady for teach-in of another handle module (only 3 min. after Power UP)
Setup
(only for MGB unicode)
X
closed
inser
ted
OFF
OFF
OFF
OFF
1 Hz
Teach-in operation, tip: T
o pr
event the interruption of teach-in operations, close door and inser
t bolt tongue
X
X
X
OFF
OFF
OFF
OFF
Positive acknowledgment after completion of teach-in operation
Diagnostics
X
X
X
OFF
OFF
OFF
ON
1 x
Err
or during teach-in/configuration or invalid DIP switch setting
err
one
-
ous
X
X
OFF
OFF
OFF
ON
2 x
FI1A/FI1B input err
or (e.g. missing test pulses, illogical switching state fr
om pr
evious switch)
X
X
X
OFF
X
X
OFF
3 x
Handle module r
ead err
or (e.g. err
or in code)
X
X
X
OFF
OFF
OFF
ON
4 x
Output fault (e.g. shor
t cir
cuit, loss of switching capability) or shor
t cir
cuit at the outputs
X
X
X
X
OFF
OFF
ON
Internal fault (e.g. component faulty
, data err
or)
X
X
X
OFF
OFF
OFF
ON
Signal sequence err
oneous (e.g. br
oken bolt tongue)
After r
emedying the cause, use the r
eset function (see chapter
15. Troubleshooting and assistance on page 36
) or briefly disconnect the power supply
. Please contact the manufactur
er if the fault could not be r
eset after r
estar
ting.
Impor
tant
: If you do not find the displayed device status in the System status table, this indicates an internal device fault. In this case, you should contact the manufactur
er
.