Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
10
(translation of the original operating instructions) 112657-12-01/15
6. Function
Together with a handle module, the interlocking module makes it possible to monitor the position of moving safety guards.
The combination also serves as a mechanical door stop at the same time.
DIP
OFF
ON
The following switch-on condition applies to the safety outputs FO1A and FO1B (also see chapters
14.2. MGB-AR
system status table on page 34
and
14.3. MGB-AP system status table on page 35
):
Configuration
System family
MGB-AR
MGB-AP
Condition
No fault in the device
TRUE
TRUE
Safety guard closed
TRUE
TRUE
Bolt tongue inserted in interlocking module
TRUE
TRUE
In case of series connection:
Signal available from the upstream switch on the safety inputs FI1A and
FI1B
In case of separate operation:
DC 24 V present at the safety inputs FI1A and FI1B
TRUE
irrelevant
FO1A and FO1B are
ON
The interlocking module detects the position of the safety guard and the position of the bolt tongue.
The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle.