Operating Instructions Safety Systems
MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
36
(Translation of the original operating instructions) 2119167-06-10/20
14. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies in case
of discrepancies with the operating instructions.
Parameter
Value
Unit
Housing material
Fiber glass reinforced plastic
Die-cast zinc, nickel-plated
Stainless steel
Dimensions
See chapter
7.4. Dimension drawing on page 13
Weight
Locking module
Handle module
Escape release
0.75
1.00
0.50
kg
Ambient temperature at U
B
= DC 24 V
-20 … +55
°C
Degree of protection
Cover not populated/populated with buttons/indi-
cators/selector switches
Cover populated with key-operated switch
Cover populated with key-operated rotary switch
FS22
IP65
IP54
IP 42
Safety class
III
Degree of contamination
3
Installation orientation
Any
Locking force F
zh
acc. to EN ISO 14119
2,000
N
Connection
4 cable entries M20x1.5 or plug connector
Conductor cross-section (rigid/flexible)
- With ferrule acc. to DIN 46228/1
- With ferrule with collar acc. to DIN 46228/1
0.13 … 1.5 (AWG 24 … AWG 16)
0.25 … 1.5
0.25 … 0.75
mm²
Operating voltage UB (reverse polarity protected,
regulated, residual ripple < 5%)
24 +10% / -15% (PELV)
V DC
Auxiliary voltage UA (reverse polarity protected,
regulated, residual ripple < 5%)
24 +10% / -15% (PELV)
V DC
Current consumption I
UB
(no load on any outputs)
80
mA
Current consumption I
UA
- With energized guard locking solenoid and
unloaded outputs OI, OL, OT and OD
- Pushbutton S (unloaded, per LED)
375
5
mA
External fuse
See chapter
12.3. Fuse protection for power supply on page 24
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
Test pulses
AR < 1000 / AP < 300
µs
Test-pulse interval
Min. 100
ms
Output voltage U
FO1A
/ U
FO1B
1)
HIGH
U
FO1A
/ U
FO1B
U
B
-2V … U
B
LOW
U
FO1A
/ U
FO1B
0 … 1
V DC
Switching current per safety output
1 … 200
mA
Switching current per control input IMP1, IMP2 and IMM
20 … 25
mA
Utilization category acc. to EN IEC 60947-5-2
DC-13 24 V 200 mA
Caution: Outputs must be protected by a free-wheeling diode in the case of inductive loads.
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
U
A
- 2V … U
A
Max. 50
mA
Rated insulation voltage U
i
30
V
Rated impulse withstand voltage U
imp
1.5
kV
Resilience to vibration
Acc. to EN IEC 60947-5-3
Switching frequency
0.25
Hz
EMC protection requirements
Acc. to EN IEC 60947-5-3
Reliability values acc. to EN ISO 13849-1
Guard lock monitoring
Control of guard locking
Category
4
4
Performance Level
PL e
PL e
PFH
D
3.7 x 10
-9
/ h
2)
2.8 x 10
-9
/ h
2)
Mission time
20
20
years
Mechanical life
1 x 10
6
- In case of use as door stop, and 1 Joule impact
energy
0.1 x 10
6
B
10D
(emergency stop)
0.065 x 10
6
Emergency stop
Operating voltage
5 … 24
V
Operating current
1 … 100
mA
Breaking capacity, max.
250
mW
Power supply LED
24
V DC
Controls and indicators
Operating voltage
UA
V
Operating current
1 … 10
mA
Breaking capacity, max.
250
mW
Power supply LED
24
V DC
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the employers’ liability insurance association certifies a PFHd of max. 2.47 x 10
-8
.