8. Electrical connection
CAUTION
Risk of damage to equipment or malfunctions as a result of incorrect connection
Ì
Before making the electrical connections, make sure that the available supply voltage matches the
voltage stated in the technical data.
Ì
The transmitter and receiver must be supplied with a voltage of 24 V DC ± 20 % (PELV, must cor-
respond to EN 60204-1 (chapter 6.4)).
Ì
The electrical connections must be made while following the wiring diagrams in these operating
instructions. No other devices are allowed to be connected to the plug connectors on the transmit-
ter and receiver.
Ì
On the usage of a power supply unit with diode bridge, the output capacitance must be at least
2000 μF for each ampere drawn.
Ì
Power devices which are a powerful source of interference must be installed in a separate location
away from the input and output circuits for signal processing. The cable routing for the safety cir-
cuits should be as far away as possible from the cables for the power circuits.
Ì
The function earth must be connected to comply with the EMC requirements.
Ì
To avoid EMC interference, the physical environmental and operating conditions at the installation
site of the device must comply with the requirements according to the standard 60204-1:2006,
section 4.4.2 (EMC).
WARNING
To ensure safety, both safety outputs must always be evaluated.
8.1. Transmitter connections
8.1.1. LCA 4 (with integrated control functions) – LCA 4 master primary connector M12, 5-pin
Table 7: M12, 5-pin - master/standard/with integrated control functions TX
Pin
Color
Name
Type
Description
1
Brown
24VDC
INPUT
Supply 24 V DC
2
White
RANGE0
Device configuration
Corresponds to the standard EN 61131-2
(see Table 8)
3
Blue
0VDC
Supply 0 V DC
4
Black
RANGE1
Device configuration
Corresponds to the standard EN 61131-2
(see Table 8)
5
Gray
FE
Earth connection
Table 8: Selection of range and TEST
Selection of range and test - (primary connector, 5-pin)
Pin 4
Pin 2
Meaning
24 V
0 V
Selection of HIGH range
0 V
24 V
Selection of LOW range
0 V
0 V
Transmitter in TEST
24V
24 V
Selection error
NOTICE
For a correct device operation mode, pins 2 and 4 for the transmitter must be connected according
to the information in Table 8 .