Inputs on the base unit ESM-F-BSN..
.
You can connect two dual-channel safety switches (e.g. two emergency stops) to
the base unit. In the example below (
Figure 6
) only one safety switch has been
connected, jumpers must therefore be fitted to the remaining safety inputs.
Base
S14
S12
S11
S13
S24
S22
S21
S23
Safety
component
Safety
component
Figure 5: Safety inputs on the ESM-F-BSN... (both inputs connected)
Base
S14
S12
S11
S13
S24
S22
S21
S23
Safety
component
Figure 6: Safety inputs on the ESM-F-BSN... (one input connected, jumper fitted