Applications
Depending on the application or the result of the risk assessment according to DIN EN ISO 13849 1, the device must be wired as shown in Fig. 5 to Fig. 15.
Emergency stop circuit
Fig. 5: Dual-channel emergency stop circuit with
short circuit and ground fault monitoring
(category 4, up to PL e).
Fig. 6: Dual-channel emergency stop circuit with
ground fault monitoring (category 3, up
to PL d).
Fig. 7: Single-channel emergency stop circuit with
ground fault monitoring (category 1, up to
PL c).
Notice:
In order to activate ground fault monitoring, S10
must be connected to PE (protective earth) on the
AC115/230V devices. With AC/DC 24 V, connect
PE only to the power supply unit according to
EN 60204-1.
Wire the start circuit in accordance with the applica-
tion according to Fig. 10 or Fig. 11.
Fig. 8: Dual-channel sliding guard monitoring with
short circuit and ground fault monitoring
(category 4, up to PL e).
Fig. 9: Dual-channel emergency stop circuit with
pnp semiconductor outputs / OSSD outputs
with short circuit detection (category 4,
up to PL e).
Starting behavior
Fig. 10: Monitored manual start. It is monitored
that the start button was opened before
the emergency stop buttons close (pre-
requisite: operating voltage must not be
interrupted).
Fig. 11: Automatic start. Max perm. delay during
closing of the safety switches on S12
and S13:
S12 before S13: 300 ms
S13 before S12: any
Feedback loop
Fig. 12: Feedback loop. Monitoring of externally
connected contactors or expansion mod-
ules.
Fig. 13: Feedback loop with automatic start. Mon-
itoring of externally connected contactors
or expansion modules.
Power supply and safety contacts
Fig. 14: Connection of the power supply to terminals
A1 and A2 (power supply according to the
technical data).
Fig. 15: Connection to switching loads on safety
contacts (example contact configura-
tion. Differing according to device type.
Switching voV corresponding to
technical data).