![EUCHNER ESL-IH-AR Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/euchner/esl-ih-ar/esl-ih-ar_operating-instructions-manual_2434748021.webp)
21
119138-05-10/15 (translation of the original operating instructions)
Operating Instructions
Safety Systems with Locking ESL-IH-AR
EN
9.3. Functional check
WARNING
Danger of fatal injury as a result of faults in installation and functional check.
Ì
Before carrying out the functional check, make sure that there are no persons in the danger area.
Ì
Observe the valid accident prevention regulations.
9.3.1. Mechanical function test
It must be possible to insert the latch on the handle module easily into the interlocking module. Close the safety guard
several times to check the function.
9.3.2. Electrical function test
After installation and any fault, the safety function must be fully checked. Proceed as follows:
1. Switch on operating voltage.
¨
The machine must not start automatically.
¨
The interlocking module carries out a self-test. The green STATE LED flashes for 10 s at 5 Hz. The green STATE LED
then flashes at regular intervals.
2. Close all safety guards.
¨
The machine must not start automatically.
¨
The green STATE LED illuminates continuously.
3. Enable operation in the control system.
4. Open the safety guard.
Ì
The machine must switch off and it must not be possible to start it as long as the safety guard is open.
Ì
The green STATE LED flashes at regular intervals.
Repeat steps 2 - 4 for each safety guard.