Operating Instructions
Transponder-Coded Safety Switch CTP-L.-AS1
14
(translation of the original operating instructions) 2124662-03-05/18
9. Installation
CAUTION
Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Safety switches and actuators must not be used as an end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about fastening the safety
switch and the actuator.
Ì
Protect the switch head against damage, as well as penetrating foreign objects such as swarf,
sand and blasting shot, etc.
Ì
Observe the min. door radii (see chapter
13.3.1. Maßzeichnung Betätiger CTP‑... auf Seite <?>
).
Ì
Observe the tightening torque for fastening the switch (max.1.4 Nm).
A clearance of 12 mm must be maintained around the actuator head (see
Figure 2
).
min. 12
min. 12
Figure 2:
Actuator head clearance